| Code | What the drive shows | Families |
|---|
| F01000 | Internal software error | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01001 | FloatingPoint exception | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01002 | Internal software error | G120, G120XA, G130, G150, S120, S150 |
| F01003 | Acknowledgment delay when accessing the memory | G120, G120XA, G130, G150, S120, S150 |
| F01005 | Firmware download for DRIVE-CLiQ component unsuccessful | G120, G120XA, G130, G150, S120, S150 |
| F01010 | Drive type unknown | G120, G120XA, G130, G150, S120, S150 |
| F01011 | Download interrupted | G130, G150, S120, S150 |
| F01012 | Project conversion error | G130, G150, S120, S150 |
| F01014 | Topology: DRIVE-CLiQ component property changed | S120, S150 |
| F01015 | Internal software error | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01018 | Booting has been interrupted several times | G115D, G120, G120C, G120XA |
| F01023 | Software timeout (internal) | G120, G120XA, G130, G150, S120, S150 |
| F01030 | Sign-of-life failure for master control | G120, G120XA, G130, G150, S120, S150 |
| F01031 | Sign-of-life failure for OFF in REMOTE | G130, G150, S120, S150 |
| F01033 | Units changeover: Reference parameter value invalid | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01034 | Units changeover: Calculation parameter values after reference value change | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01036 | ACX: Parameter back-up file missing | G120, G120XA, G130, G150, S120, S150 |
| F01038 | ACX: Loading the parameter back-up file unsuccessful | G120, G120XA, G130, G150, S120, S150 |
| F01039 | ACX: Writing to the parameter back-up file was unsuccessful | G120, G120XA, G130, G150, S120, S150 |
| F01040 | Save parameter settings and carry out a POWER ON | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01041 | Parameter save necessary | G130, G150, S120, S150 |
| F01042 | Parameter error during project download | G120, G120XA, G130, G150, S120, S150 |
| F01043 | Fatal error at project download | G120, G120XA, G130, G150, S120, S150 |
| F01050 | Memory card and device incompatible | G130, G150, S120, S150 |
| F01054 | CU: System limit exceeded | G120, G120XA, G130, G150, S120, S150 |
| F01055 | CU: Internal error (SYNO of port and application not identical) | G130, G150, S120, S150 |
| F01056 | CU: Internal error (clock cycle of parameter group already assigned differently) | G130, G150, S120, S150 |
| F01057 | CU: Internal error (different DRIVE-CLiQ type for the slave) | G130, G150, S120, S150 |
| F01058 | CU: Internal error (slave missing in topology) | G130, G150, S120, S150 |
| F01059 | CU: Internal error (port does not exist) | G130, G150, S120, S150 |
| F01060 | CU: Internal error (parameter group not available) | G130, G150, S120, S150 |
| F01061 | CU: Internal error (application not known) | G130, G150, S120, S150 |
| F01063 | CU: Internal error (PDM) | G130, G150, S120, S150 |
| F01068 | CU: Data memory memory overflow | G120, G120XA, G130, G150, S120, S150 |
| F01070 | Project/firmware is being downloaded to the memory card | G130, G150, S120, S150 |
| F01072 | Memory card restored from the backup copy | G120, G120XA, G130, G150, S120, S150 |
| F01082 | Parameter error when powering up from data backup | G130, G150, S120, S150 |
| F01105 | CU: Insufficient memory | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01107 | Save to memory card unsuccessful | G120, G120XA, G130, G150, S120, S150 |
| F01110 | CU: More than one SINAMICS G on one Control Unit | G130, G150, S120, S150 |
| F01111 | CU: Mixed operation of drive units illegal | G130, G150, S120, S150 |
| F01112 | CU: Power unit not permissible | G120, G120XA, G130, G150, S120, S150 |
| F01120 | Terminal initialization has failed | G120, G120XA, G130, G150, S120, S150 |
| F01122 | Frequency at the measuring probe input too high | G115D, G120, G120C, G130, G150, S120, S150 |
| F01150 | CU: Number of instances of a drive object type exceeded | G130, G150, S120, S150 |
| F01151 | CU: Number of drive objects of a category exceeded | G130, G150, S120, S150 |
| F01152 | CU: Invalid constellation of drive object types | G120, G120XA, G130, G150, S120, S150 |
| F01200 | CU: Time slice management internal software error | G130, G150, S120, S150 |
| F01205 | CU: Time slice overflow | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01221 | CU: Bas clk cyc too low | G130, G150, S120, S150 |
| F01222 | CU: Basic clock cycle too low (computing time for communication not available) | G130, G150, S120, S150 |
| F01250 | CU: CU-EEPROM incorrect read-only data | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01255 | CU: Option Board EEPROM read-only data error | G130, G150, S120, S150 |
| F01257 | CU: Firmware version out of date | G120, G120XA |
| F01275 | Hardware description error | S120, S150 |
| F01303 | Component does not support the required function | G130, G150, S120, S150 |
| F01305 | Topology: Component number missing | G130, G150, S120, S150 |
| F01325 | Topology: Component number not present in target topology | G130, G150, S120, S150 |
| F01340 | Topology: Too many components on one line | G120, G120XA, G130, G150, S120, S150 |
| F01354 | Topology: Actual topology indicates an illegal component | G130, G150, S120, S150 |
| F01355 | Topology: Actual topology changed | G130, G150, S120, S150 |
| F01356 | Topology: There is a defective DRIVE-CLiQ component | G130, G150, S120, S150 |
| F01357 | Topology: Two Control Units identified on the DRIVE-CLiQ line | G130, G150, S120, S150 |
| F01359 | Topology: DRIVE-CLiQ performance not sufficient | G130, G150, S120, S150 |
| F01360 | Topology: Actual topology not permissible | G130, G150, S120, S150 |
| F01375 | Topology: Connection duplicated between two components | G130, G150, S120, S150 |
| F01380 | Topology: Actual topology EEPROM defective | G130, G150, S120, S150 |
| F01510 | BICO: Signal source is not float type | G120, G120XA, G130, G150, S120, S150 |
| F01511 | BICO: Interconnection with different scalings | G120, G120XA, G130, G150, S120, S150 |
| F01512 | BICO: No scaling available | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| F01513 | BICO: Interconnection cross DO with different scalings | G120, G130, G150, S120, S150 |
| F01515 | BICO: Writing to parameter not permitted as the master control is active | G120, G120XA, G130, G150, S120, S150 |
| F01600 | SI P1 (CU): STOP A initiated | G120, G120C, G130, G150, S120, S150 |
| F01612 | SI P1 (CU): STO inputs for power units connected in parallel different | G130, G150, S120, S150 |
| F01625 | SI P1 (CU): Sign-of-life error in safety data | G120, G120C, G130, G150, S120, S150 |
| F01630 | SI P1 (CU): Brake control error | G130, G150, S120, S150 |
| F01632 | SI P1 (CU): shutoff valve control/feedback signal error | S120, S150 |
| F01640 | SI P1 (CU): component replacement identified and acknowledgment/save required | G120, G130, G150, S120, S150 |
| F01641 | SI P1 (CU): component replacement identified and save required | G120, G130, G150, S120, S150 |
| F01649 | SI P1 (CU): Internal software error | G120, G130, G150, S120, S150 |
| F01650 | SI P1 (CU): Acceptance test required | G120, G120C, G130, G150, S120, S150 |
| F01651 | SI P1 (CU): Synchronization safety time slices unsuccessful | G120, G130, G150, S120, S150 |
| F01653 | SI P1 (CU): PROFIBUS/PROFINET configuration error | G120, G130, G150, S120, S150 |
| F01655 | SI P1 (CU): Align monitoring functions | G120, G130, G150, S120, S150 |
| F01656 | SI CU: Parameter monitoring channel 2 error | G120, G130, G150, S120, S150 |
| F01657 | SI P1 (CU): PROFIsafe telegram number invalid | G130, G150, S120, S150 |
| F01658 | SI P1 (CU): PROFIsafe telegram number not suitable | G120, G130, G150, S120, S150 |
| F01660 | SI P1 (CU): Safety-related functions not supported | G120, G130, G150, S120, S150 |
| F01661 | SI P1 (CU): Simulation of the safety inputs active | G120, G130, G150, S120, S150 |
| F01662 | Error internal communications | G115D, G120, G120C, G120XA |
| F01663 | SI P1 (CU): Copying the SI parameters rejected | G120, G130, G150, S120, S150 |
| F01664 | SI P1 (CU): No automatic firmware update | G130, G150, S120, S150 |
| F01665 | SI P1 (CU): System is defective | G120, G130, G150, S120, S150 |
| F01671 | SI Motion: Parameterization encoder error | G130, G150, S120, S150 |
| F01672 | SI P1 (CU): Motor Module software/hardware incompatible | G130, G150, S120, S150 |
| F01673 | SI Motion: Sensor Module software/hardware incompatible | G130, G150, S120, S150 |
| F01674 | SI Motion P1 (CU): Safety function not supported by PROFIsafe telegram | G130, G150, S120, S150 |
| F01675 | SI Motion P1: settings in the PROFIBUS/PROFINET controller not permissible | S120, S150 |
| F01679 | SI CU: Safety parameter settings and topology changed, warm restart/POWER ON | G130, G150, S120, S150 |
| F01680 | SI Motion P1 (CU): Checksum error safety monitoring functions | G120, G130, G150, S120, S150 |
| F01681 | SI Motion P1 (CU): Incorrect parameter value | G120, G130, G150, S120, S150 |
| F01682 | SI Motion P1 (CU): Monitoring function not supported | G120, G130, G150, S120, S150 |
| F01683 | SI Motion P1 (CU): SOS/SLS enable missing | G120, G130, G150, S120, S150 |
| F01684 | SI Motion P1 (CU): Safely limited position limit values interchanged | G130, G150, S120, S150 |
| F01685 | SI Motion P1 (CU): Safely-Limited Speed limit value too high | G130, G150, S120, S150 |
| F01686 | SI Motion: Illegal parameterization cam position | G130, G150, S120, S150 |
| F01687 | SI Motion: Illegal parameterization modulo value SCA (SN) | G130, G150, S120, S150 |
| F01688 | SI Motion CU: Actual value synchronization not permissible | G130, G150, S120, S150 |
| F01690 | SI Motion: Data save problem for the NVRAM | G120, G130, G150, S120, S150 |
| F01692 | SI Motion P1 (CU): Parameter value not permitted for encoderless | G120, G130, G150, S120, S150 |
| F01694 | SI Motion CU: Firmware version Motor Module/Hydraulic Module older Control Unit | G130, G150, S120, S150 |
| F01773 | SI Motion P1 (CU): Test stop failsafe digital output error | G130, G150, S120, S150 |
| F01786 | SCC signal source changed | G130, G150, S120, S150 |
| F01787 | SBT motor type different | G130, G150, S120, S150 |
| F01800 | DRIVE-CLiQ: Hardware/configuration error | G130, G150, S120, S150 |
| F01910 | Fieldbus: setpoint timeout | G115D, G120, G120C, G130, G150, S120, S150 |
| F01911 | PB/PN: clock cycle synchronous operation clock cycle failure | G130, G150, S120, S150 |
| F01912 | PB/PN: clock cycle synchronous operation sign-of-life failure | G130, G150, S120, S150 |
| F01913 | COMM INT: Monitoring time sign-of-life expired | S120, S150 |
| F01914 | COMM INT: Monitoring time configuration expired | S120, S150 |
| F01915 | PB/PN: clock cycle synchronous operation sign-of-life failure drive object 1 | S120, S150 |
| F01946 | PROFIBUS: Connection to the Publisher aborted | G120, G120XA, G130, G150, S120, S150 |
| F01950 | PB/PN: clock cycle synchronous operation synchronization unsuccessful | G130, G150, S120, S150 |
| F01951 | CU SYNC: Synchronization application clock cycle missing | G120, G130, G150, S120, S150 |
| F01952 | CU DRIVE-CLiQ: Synchronization of component not supported | G130, G150, S120, S150 |
| F01954 | CU DRIVE-CLiQ: Synchronization unsuccessful | G130, G150, S120, S150 |
| F01978 | CBE41: overtemperature fault | S120, S150 |