Fault · SINAMICS G130, G150, S120, S150

F01057CU: Internal error (different DRIVE-CLiQ type for the slave)

What it means

F01057 is an internal error of the Control Unit (CU): the same slave component has been requested with different DRIVE-CLiQ types — the manual names hps_ps and hps_enc as examples of these types. The message is documented for the G130, G150, S120 and S150 and is always raised by the Control Unit. The manual adds that the fault is only for internal Siemens troubleshooting, so no deeper analysis is documented for the user; the fault value in r0949 identifies the internal method involved.

Why it appears

  • The same slave component has been requested with different DRIVE-CLiQ types (hps_ps, hps_enc, ...).
  • No further causes are documented — the manual marks the fault as only for internal Siemens troubleshooting.

What to check

  1. Read the fault value from r0949; the manual specifies that it is interpreted hexadecimal and contains the Method ID.
  2. Contact Technical Support and quote the fault F01057 together with the fault value — the manual gives this as the only remedy and describes no check or repair the user can perform.

Reading the message value

  • The drive stores the fault value in r0949; it must be interpreted hexadecimal.
  • Content of the fault value: the Method ID.

Parameters the manual names

  • r0949 — fault value of this fault: read it (interpret hexadecimal) to obtain the Method ID before contacting Technical Support.

Acknowledging and restarting

Acknowledge the fault immediately once it is displayed. The drive itself takes no protective action for this fault, and the manual describes no user-side repair — contacting Technical Support is the only remedy given, so clearing the message does not remove the underlying internal error.

The same on every family

Every manual that describes F01057 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2572
G130, G150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1385

The drives this code lives on

F01057 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01057 mean on a SINAMICS drive?

It is an internal error of the Control Unit: the same slave component has been requested with different DRIVE-CLiQ types (hps_ps, hps_enc, ...). The manual marks the message as only for internal Siemens troubleshooting.

How do I clear fault F01057?

Acknowledge the fault immediately and contact Technical Support — the manual gives no user-side repair. Quote the fault value from r0949 so the internal method involved is known.

What is the fault value of F01057?

It is stored in r0949 and must be interpreted hexadecimal; its content is the Method ID.

Which converters can report F01057?

The message is documented for the G130, G150, S120 and S150 and is raised by the Control Unit.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F01xxx group · SINAMICS manuals · Siemens manuals