Fault · SINAMICS G130, G150, S120, S150

F01060CU: Internal error (parameter group not available)

What it means

F01060 is raised by the Control Unit when a parameter group that has been requested — the manual names IREG and NREG as examples — is not offered by the slave type involved.

The drive stores the fault value in r0949; the value is the Method ID, and the manual says to interpret it hexadecimal.

Both manuals that describe this fault, for the G130/G150 and the S120/S150, give the same cause and the same remedy, so no family-specific difference applies.

The manual adds a note: the fault is relevant only for internal Siemens troubleshooting.

Why it appears

  • A parameter group (IREG or NREG, for example) was requested from a slave type that does not offer that group.

What to check

  1. There is no on-site check to perform: the manual limits this fault to internal Siemens troubleshooting and names no measure for the user.
  2. Contact Technical Support and report the fault value stored in r0949 — the Method ID, interpreted hexadecimal.

Reading the message value

  • The fault value is stored in r0949.
  • The value is the Method ID of the request; the manual instructs interpreting it hexadecimal.

Parameters the manual names

  • r0949 — fault value: for this fault it carries the Method ID, interpreted hexadecimal.

Acknowledging and restarting

The fault is cleared by acknowledging it; the manual describes no further reset step for F01060.

The remedy the manual prints — contacting Technical Support — is what addresses the underlying cause.

The same on every family

Every manual that describes F01060 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2573
G130, G150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1386

The drives this code lives on

F01060 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01060 mean on a SINAMICS drive?

The Control Unit reports an internal error: a parameter group (IREG or NREG, for example) was requested that the slave type does not offer. The manual states the fault is only for internal Siemens troubleshooting.

How is F01060 fixed?

The manual names no on-site measure; the remedy is to contact Technical Support. Report the fault value in r0949 — the Method ID, interpreted hexadecimal.

Where can I read the fault value of F01060?

In r0949. The value is the Method ID, and the manual says to interpret it hexadecimal.

Do the G130/G150 and the S120/S150 treat F01060 differently?

No. Both manuals give the same cause and the same remedy for this fault, so no family-specific difference applies.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F01xxx group · SINAMICS manuals · Siemens manuals