SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Fault · SINAMICS G130, G150, S120, S150

F01058CU: Internal error (slave missing in topology)

What it means

The Control Unit (CU) reports F01058 when a slave component that has been requested is not present in the topology. The manual treats this as an internal error and notes that it is intended only for internal Siemens troubleshooting, so no on-site corrective procedure is described for it.

Why it appears

  • The requested slave component does not exist in the topology.

What to check

  1. Contact Technical Support — this is the only remedy the manual gives for F01058. The fault is meant for internal Siemens troubleshooting, so state the fault value from r0949 when reporting the case; the manual describes no corrective action to be carried out on the converter itself.

Reading the message value

  • The drive enters the Method ID into r0949; the value must be interpreted hexadecimal.
  • No decoding of individual Method IDs is given, because the message value serves only internal Siemens troubleshooting.

Parameters the manual names

  • r0949 — read out to obtain the fault value of F01058; it holds the Method ID (interpret hexadecimal).

Acknowledging and restarting

F01058 can be acknowledged immediately, and the drive takes no automatic action in response to the fault. Because the message signals an internal error whose only described remedy is contacting Technical Support, acknowledgment does not eliminate the cause of the message.

The same on every family

Every manual that describes F01058 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2572
G130, G150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1385

The drives this code lives on

F01058 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS fault F01058 mean?

It is an internal error of the Control Unit: a slave component that was requested does not exist in the topology. The manual marks the message as only for internal Siemens troubleshooting.

How do I fix fault F01058?

The only remedy the manual gives is to contact Technical Support; no on-site corrective action is described. The fault value in r0949 (the Method ID) is the internal diagnostic information for that case.

Which parameter holds the fault value of F01058?

r0949. It contains the Method ID, which must be interpreted hexadecimal.

Can F01058 be reset and the drive restarted?

The fault can be acknowledged immediately and the drive takes no automatic action, but acknowledgment does not remove the internal cause. The manual's only remedy is to contact Technical Support.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F01xxx group · SINAMICS manuals · Siemens manuals