Fault · SINAMICS G120, G130, G150, S120, S150

F01513BICO: Interconnection cross DO with different scalings

What it means

F01513 is raised when a requested BICO interconnection is established between two different drive objects whose scalings do not match: the BICO output has different normalized units than the BICO input, or both use the same normalized unit but the reference values of the two drive objects differ. The interconnection is nevertheless established — the drive converts the signal between the BICO output and the BICO input using a factor calculated from the reference values. Depending on the drive's configuration, the same condition can also be output as an alarm or as a message without reaction.

Why it appears

  • A BICO interconnection between different drive objects in which the BICO output and the BICO input have different normalized units — for example a voltage output connected to a current input. The drive then calculates the factor p2002/p2001 between the output and the input (p2002 contains the reference value for current, p2001 the reference value for voltage).
  • A BICO interconnection between different drive objects in which the output and the input use the same normalized unit but the reference values differ — for example a voltage output in drive object 1 (DO1) connected to a voltage input in drive object 2 (DO2) whose voltage reference values differ. The drive then calculates the factor p2001(DO1)/p2001(DO2).

What to check

  1. Read the fault value in r0949 as a decimal number: it contains the parameter number of the BICO input (signal sink) to which the interconnection leads.
  2. No remedial action is necessary: the requested BICO interconnection has been established, and the drive converts the signal between the BICO output and the BICO input using the reference values.

Reading the message value

  • Interpreted as a decimal number, the fault value in r0949 contains the parameter number of the BICO input (signal sink).
  • The message value shows the entry as «Parameter: %1», where %1 stands for the parameter concerned.

Parameters the manual names

  • p2001 — reference voltage; it enters the conversion factor when two drive objects with different voltage reference values are interconnected (factor p2001(DO1)/p2001(DO2)).
  • p2002 — reference current; together with p2001 it forms the conversion factor p2002/p2001 that the drive calculates when the BICO output and the BICO input have different normalized units.
  • r0949 — fault value; read it here as a decimal number to obtain the parameter number of the BICO input (signal sink).

Acknowledging and restarting

The drive does not intervene in operation for this condition, so no restart procedure is required. In the fault variant the message is acknowledged immediately; when the same condition is output as an alarm or as a message without reaction, no acknowledgement is needed either.

What differs between the drive families

Straight from the manuals' own fields — F01513 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1425
S120, S150NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2616
G120NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)SINAMICS G120 · p. 835

The drives this code lives on

F01513 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01513 mean on a SINAMICS drive?

It reports that a BICO interconnection was established between different drive objects whose scalings differ — either the normalized units of output and input differ, or the reference values of the two drive objects differ. The drive converts the signal between output and input using the reference values.

How do I clear fault F01513?

The manual states that no remedy is necessary: the interconnection remains in place and the drive performs the conversion automatically. In the fault variant the message is acknowledged immediately.

Which parameter has triggered F01513?

Read the fault value in r0949 as a decimal number — it contains the parameter number of the BICO input (signal sink). The message value also names the parameter concerned.

Does F01513 stop the drive?

No. The drive takes no action, and depending on the configuration the condition may also appear only as an alarm or as a message without reaction.