Fault · SINAMICS G120, G120XA, G130, G150, S120, S150

F01107CU: Save to memory card unsuccessful

What it means

F01107 is reported by the Control Unit (CU) when a data save could not be carried out successfully. On the G120 and G120XA the manual words this as a save to the memory card; on the S120, S150, G130 and G150 the same fault is described as a save in the non-volatile memory. The drive puts the fault value behind the message into r0949.

Why it appears

  • A data save was not able to be carried out successfully — the manual describes this as a save to the memory card on the G120 and G120XA, and as a save in the non-volatile memory on the S120, S150, G130 and G150.
  • The memory card — respectively the non-volatile memory — is defective.
  • Insufficient space on the memory card, respectively in the non-volatile memory.

What to check

  1. Try to save again.
  2. If the save fails again, replace the memory card or the Control Unit.

Reading the message value

The drive writes the fault value to r0949; interpret it as a decimal number. On the G120 and G120XA the value shows at which step the save failed:

  • 1: The file on the RAM was not able to be opened.
  • 2: The file on the RAM was not able to be read.
  • 3: A new directory could not be created on the memory card.
  • 4: A new file could not be created on the memory card.
  • 5: A new file could not be written on the memory card.

On the S120, S150, G130 and G150 the manual gives no decoding for the user: the fault value there is only for internal Siemens troubleshooting.

Parameters the manual names

  • r0949 — fault value of this message: read it as a decimal number to see which step of the save failed (values 1 to 5 on the G120/G120XA).

Acknowledging and restarting

The drive takes no automatic action in response to this fault. Acknowledge it immediately — for example at the operator panel or in the commissioning tool — and then repeat the save. If the fault appears again, replace the memory card or the Control Unit as described above.

What differs between the drive families

Straight from the manuals' own fields — F01107 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
G120NONEIMMEDIATELYHardware/software error (1)SINAMICS G120 · p. 831
G120XANONEIMMEDIATELYSINAMICS G120XA PN converter · p. 1108
S120, S150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2578
G130, G150NONEIMMEDIATELYHardware/software error (1)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1391

The drives this code lives on

F01107 is described for G120, G120XA, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01107 on a SINAMICS drive mean?

The Control Unit could not complete a data save — to the memory card on the G120 and G120XA, or into the non-volatile memory on the S120, S150, G130 and G150.

How do I fix F01107?

Try to save again. If the fault occurs once more, replace the memory card or the Control Unit.

What does the fault value of F01107 tell me?

Read r0949 as a decimal number. On the G120 and G120XA, values 1 to 5 show which step of the save failed — for example, 5 means a new file could not be written on the memory card. On the other units the value is only for internal Siemens troubleshooting.

Why does my drive keep running with F01107?

This fault causes no automatic response from the drive; it only reports that the save was not completed. Acknowledge it immediately and repeat the save.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.