Fault · SINAMICS G130, G150, S120, S150

F01050Memory card and device incompatible

What it means

F01050 is raised when the memory card inserted in the Control Unit (CU) and the device type do not match, i.e. the card was not made for the device it is plugged into. The manual's example is a memory card for SINAMICS S inserted in a SINAMICS G converter. While the fault is active the drive coasts down and must be acknowledged before it will start again.

Why it appears

  • The memory card and the device type do not match — for example, a memory card for SINAMICS S is inserted in a SINAMICS G converter.

What to check

  1. Insert the matching memory card, so that the card belongs to the device it is used in.
  2. Alternatively, keep the memory card and use the matching Control Unit (CU) or power unit, so that card and device type match again.

Acknowledging and restarting

Remove the mismatch first: insert the matching memory card or use the matching Control Unit (CU) or power unit. The fault is then acknowledged immediately, and only after acknowledgment will the drive start again.

What differs between the drive families

Straight from the manuals' own fields — F01050 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150Infeed: OFF2 (NONE, OFF1) Servo: OFF2 (NONE, OFF1, OFF3) Vector: OFF2 (NONE, OFF1, OFF3) Hla: OFF2 (NONE, OFF1, OFF3)IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2570
G130, G150Vector: OFF2 (NONE, OFF1, OFF3) Infeed: OFF2 (NONE, OFF1)IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1383

The drives this code lives on

F01050 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01050 mean in SINAMICS?

It means the memory card inserted in the Control Unit does not match the device type — for example, a memory card for SINAMICS S inserted in a SINAMICS G converter.

How do I clear SINAMICS fault F01050?

Insert the matching memory card, or use the matching Control Unit or power unit so that card and device type agree. Then acknowledge the fault immediately and restart the drive.

Which SINAMICS drives can report F01050?

The fault is described for SINAMICS G130, G150, S120 and S150; the message comes from the Control Unit (CU).

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F01xxx group · SINAMICS manuals · Siemens manuals