Fault · SINAMICS G130, G150, S120, S150

F01354Topology: Actual topology indicates an illegal component

What it means

F01354 is raised when the actual topology indicates at least one illegal component: a component that is not permissible at this Control Unit, or one that is not permissible in combination with another connected component. While the fault is active, the drive coasts down and Pulse enable is prevented.

Why it appears

  • A component is connected at this Control Unit although it is not permissible there.
  • A component is not permissible in combination with another connected component.

What to check

  1. Read the fault value in r0949 hexadecimal as yyxx: yy identifies the component number and xx the cause, so you know which component is illegal and why.
  2. Remove the illegal components.
  3. Restart the system.
  4. Acknowledge the fault immediately afterwards.

Reading the message value

  • The drive enters the fault cause as %1 and the component number as %2 in the message value.
  • The fault value is stored in r0949 and must be interpreted hexadecimal as yyxx hex: yy = component number, xx = cause.
  • xx = 1: Component at this Control Unit not permissible.
  • xx = 2: Component in combination with another component not permissible.

Parameters the manual names

  • r0949 (fault value): read it hexadecimal here to identify the component number (yy) and the cause (xx) of the illegal-component detection.

Acknowledging and restarting

The fault is acknowledged immediately. Remove the illegal components first, then restart the system and acknowledge the fault. Because the drive coasts down and pulse enable is prevented while the fault is present, it will not return to operation until the illegal components have been removed and the fault has been acknowledged.

The same on every family

Every manual that describes F01354 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150OFF2IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1406
S120, S150OFF2IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2595

The drives this code lives on

F01354 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F01354 mean on a SINAMICS drive?

The actual topology indicates at least one illegal component: either a component that is not permissible at this Control Unit, or one that is not permissible in combination with another connected component. Pulse enable is prevented while the fault is active.

How do I fix fault F01354?

Read the fault value in r0949 hexadecimal as yyxx (yy = component number, xx = cause), remove the illegal components, restart the system and acknowledge the fault immediately.

What is the fault value of F01354?

r0949 holds yyxx hex, where yy is the component number and xx the cause: xx = 1 means the component is not permissible at this Control Unit, xx = 2 means it is not permissible in combination with another component.

Why does the drive refuse to enable pulses with F01354?

Pulse enable is prevented for this fault. The drive only returns to operation after the illegal components have been removed, the system has been restarted and the fault has been acknowledged.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.