| Code | What the drive shows | Families |
|---|
| F33100 | Encoder 3: Zero mark distance error | G130, G150, S120, S150 |
| F33101 | Encoder 3: Zero mark failed | G130, G150, S120, S150 |
| F33103 | Encoder 3: Signal level zero track (track R) outside tolerance | G130, G150, S120, S150 |
| F33110 | Encoder 3: Serial communications error | G130, G150, S120, S150 |
| F33111 | Encoder 3: Encoder signals an internal error (detailed information) | G130, G150, S120, S150 |
| F33112 | Encoder 3: Encoder signals an internal error | G130, G150, S120, S150 |
| F33115 | Encoder 3: Signal level track A or B too low | G130, G150, S120, S150 |
| F33116 | Encoder 3: Amplitude error monitoring track A + B | G130, G150, S120, S150 |
| F33117 | Encoder 3: Inversion error signals A/B/R | G130, G150, S120, S150 |
| F33118 | Encoder 3: Speed change not plausible | G130, G150, S120, S150 |
| F33120 | Encoder 3: Encoder power supply fault | G130, G150, S120, S150 |
| F33121 | Encoder 3: Coarse position error | G130, G150, S120, S150 |
| F33122 | Encoder 3: Sensor Module hardware fault | G130, G150, S120, S150 |
| F33123 | Encoder 3: Signal level A/B outside tolerance | G130, G150, S120, S150 |
| F33125 | Encoder 3: Signal level track A or B too high | G130, G150, S120, S150 |
| F33126 | Encoder 3: Signal level track A or B too high | G130, G150, S120, S150 |
| F33129 | Encoder 3: Position difference hall sensor/track C/D and A/B too large | G130, G150, S120, S150 |
| F33130 | Encoder 3: Zero mark and position error from the coarse synchronization | G130, G150, S120, S150 |
| F33131 | Encoder 3: Position deviation incremental/absolute too high | G130, G150, S120, S150 |
| F33135 | Encoder 3: Fault when determining the position (singleturn) | G130, G150, S120, S150 |
| F33136 | Encoder 3: Fault when determining the position (multiturn) | G130, G150, S120, S150 |
| F33137 | Encoder 3: Fault when determining the position (singleturn) | G130, G150, S120, S150 |
| F33138 | Encoder 3: Fault when determining the position (multiturn) | G130, G150, S120, S150 |
| F33150 | Encoder 3: Initialization error | G130, G150, S120, S150 |
| F33151 | Encoder 3: Encoder speed for initialization AB too high | G130, G150, S120, S150 |
| F33152 | Encoder 3: Max. signal frequency (track A/B) exceeded | G130, G150, S120, S150 |
| F33153 | Encoder 3: Identification error | G130, G150, S120, S150 |
| F33160 | Encoder 3: Analog sensor channel A failed | G130, G150, S120, S150 |
| F33161 | Encoder 3: Analog sensor channel B failed | G130, G150, S120, S150 |
| F33163 | Encoder 3: Analog sensor position value exceeds limit value | G130, G150, S120, S150 |
| F33405 | Encoder 3: Temperature in the encoder evaluation exceeded | G130, G150, S120, S150 |
| F33500 | Encoder 3: Position tracking traversing range exceeded | G130, G150, S120, S150 |
| F33501 | Encoder 3: Position tracking encoder position outside tolerance window | G130, G150, S120, S150 |
| F33502 | Encoder 3: Encoder with measuring gear without valid signals | G130, G150, S120, S150 |
| F33503 | Encoder 3: Position tracking cannot be reset | G130, G150, S120, S150 |
| F33801 | Encoder 3 DRIVE-CLiQ: Sign-of-life missing | G130, G150, S120, S150 |
| F33804 | Encoder 3: Sensor Module checksum error | G130, G150, S120, S150 |
| F33805 | Encoder 3: EEPROM checksum error | G130, G150, S120, S150 |
| F33806 | Encoder 3: Initialization error | G130, G150, S120, S150 |
| F33812 | Encoder 3: Requested cycle or RX-/TX timing not supported | G130, G150, S120, S150 |
| F33813 | Encoder 3: Hardware logic unit failed | G130, G150, S120, S150 |
| F33820 | Encoder 3 DRIVE-CLiQ: Telegram error | G130, G150, S120, S150 |
| F33835 | Encoder 3 DRIVE-CLiQ: Cyclic data transfer error | G130, G150, S120, S150 |
| F33836 | Encoder 3 DRIVE-CLiQ: Send error for DRIVE-CLiQ data | G130, G150, S120, S150 |
| F33837 | Encoder 3 DRIVE-CLiQ: Component fault | G130, G150, S120, S150 |
| F33845 | Encoder 3 DRIVE-CLiQ: Cyclic data transfer error | G130, G150, S120, S150 |
| F33850 | Encoder 3: Encoder evaluation internal software error | G130, G150, S120, S150 |
| F33851 | Encoder 3 DRIVE-CLiQ (CU): Sign-of-life missing | G130, G150, S120, S150 |
| F33860 | Encoder 3 DRIVE-CLiQ (CU): Telegram error | G130, G150, S120, S150 |
| F33875 | Encoder 3: power supply voltage failed | G130, G150, S120, S150 |
| F33885 | Encoder 3 DRIVE-CLiQ (CU): Cyclic data transfer error | G130, G150, S120, S150 |
| F33886 | Encoder 3 DRIVE-CLiQ (CU): Error when sending DRIVE-CLiQ data | G130, G150, S120, S150 |
| F33887 | Encoder 3 DRIVE-CLiQ (CU): Component fault | G130, G150, S120, S150 |
| F33895 | Encoder 3 DRIVE-CLiQ (CU): Alternating cyclic data transfer error | G130, G150, S120, S150 |
| F33896 | Encoder 3 DRIVE-CLiQ (CU): Inconsistent component properties | G130, G150, S120, S150 |
| F33899 | Encoder 3: Unknown fault | G130, G150, S120, S150 |
| F33905 | Encoder 3: Encoder parameterization error | G130, G150, S120, S150 |
| F33912 | Encoder 3: Device combination is not permissible | G130, G150, S120, S150 |
| F33916 | Encoder 3: Encoder parameterization error | G130, G150, S120, S150 |
| F33950 | Encoder 3: Internal software error | G130, G150, S120, S150 |