What it means
F33804 is raised when a checksum error occurs while the program memory on the Sensor Module Encoder 3 is being read out. The S120/S150 manual titles the condition Encoder 3: Sensor Module checksum error, while on G130 and G150 the same fault appears as Encoder 3: Checksum error — in both cases the affected component is the Sensor Module Encoder 3 and the descriptions match. Depending on the drive's configuration, the same condition can also be signalled as an alarm or with no reaction at all.
Why it appears
- A checksum error occurred when the program memory on the Sensor Module (Encoder 3) was read out — this is the only cause the manuals give for this fault.
What to check
- Carry out a POWER ON: switch the converter off and switch it on again.
- Upgrade the firmware to a later version (>= V2.6 HF3, >= V4.3 SP2, >= V4.4).
- Check that the permissible ambient temperature for the component is maintained.
- Replace the Sensor Module.
Reading the message value
- The drive stores the fault value in r0949; interpret it hexadecimal, in the form yyyyxxxx hex.
- yyyy — memory area involved.
- xxxx — difference between the checksum at POWER ON and the actual checksum.
Parameters the manual names
- r0949 — read the fault value of F33804 here and decode it hexadecimal: the first four digits (yyyy) give the memory area involved, the last four digits (xxxx) give the difference between the checksum at POWER ON and the actual checksum.
Acknowledging and restarting
F33804 is acknowledged with a POWER ON — switch the converter off and on again; the drive will not restart until this power cycle has been carried out. Note that this same step heads the remedy list, so the first fix attempt is also the acknowledgement. If the drive is configured to signal the condition only as an alarm or with no reaction, no acknowledgement is required.
What differs between the drive families
Straight from the manuals' own fields — F33804 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | Servo: OFF1 (IASC/DCBRK, NONE, OFF2, OFF3) Vector: OFF1 (IASC/DCBRK, NONE, OFF2, OFF3) Hla: OFF1 (NONE, OFF2, OFF3) | POWER ON (IMMEDIATELY) | Hardware/software error (1) | Sensor Module Encoder 3 | SINAMICS S120, S150 List Manual · p. 3165 |
| G130, G150 | OFF1 (IASC/DCBRK, NONE, OFF2, OFF3) | POWER ON (IMMEDIATELY) | Hardware/software error (1) | Sensor Module Encoder 3 | SINAMICS G130, G150 List Manual · p. 1837 |
The drives this code lives on
F33804 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does fault F33804 mean on a SINAMICS drive?
It is a checksum error that occurred when the program memory on Sensor Module Encoder 3 was read out. The manuals describe it for G130, G150, S120 and S150.
How do I clear F33804?
Carry out a POWER ON, i.e. switch the drive off and on. If the fault returns, upgrade the firmware (at least V2.6 HF3, V4.3 SP2 or V4.4), check that the permissible ambient temperature is maintained, and finally replace the Sensor Module.
What is in the fault value of F33804 in r0949?
A hexadecimal value of the form yyyyxxxx: yyyy names the memory area involved and xxxx is the difference between the checksum at POWER ON and the actual checksum.
Can F33804 also appear as an alarm?
Yes. Depending on the drive's configuration, the same condition can be signalled as an alarm or with no reaction instead of a fault.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the F33xxx group · SINAMICS manuals · Siemens manuals
