| Code | What the drive shows | Families |
|---|
| A30010 | Power unit: Sign-of-life error cyclic data | G130, G150, S120, S150 |
| A30016 | Power unit: Load supply switched off | G120, G120XA, G130, G150, S120, S150 |
| A30030 | Power unit: Internal overtemperature alarm | G120, G120XA, G130, G150, S120, S150 |
| A30031 | Power unit: Hardware current limiting in phase U | G120, G120XA, G130, G150, S120, S150 |
| A30032 | Power unit: Hardware current limiting in phase V | G120, G120XA, G130, G150, S120, S150 |
| A30033 | Power unit: Hardware current limiting in phase W | G120, G120XA, G130, G150, S120, S150 |
| A30034 | Power unit: Internal overtemperature | G120, G120XA, G130, G150, S120, S150 |
| A30041 | Power unit: Undervolt 24/48 V alarm | G130, G150, S120, S150 |
| A30042 | Power unit: Fan has reached the maximum operating hours | G120, G120XA, G130, G150, S120, S150 |
| A30044 | Power unit: Overvolt 24/48 V alarm | G130, G150, S120, S150 |
| A30046 | Power unit: Undervoltage alarm | G130, G150, S120, S150 |
| A30048 | Power unit: fan defective | G130, G150, S120, S150 |
| A30054 | Power unit: Undervoltage when opening the brake | G120, G130, G150, S120, S150 |
| A30057 | Power unit: Line asymmetry | G120, G120XA, G130, G150, S120, S150 |
| A30065 | Voltage measured values not plausible | G120, G130, G150, S120, S150 |
| A30066 | Power unit: overtemperature, alarm capacitor air discharge | S120, S150 |
| A30073 | Actual value/setpoint preprocessing no longer synchronous | G130, G150, S120, S150 |
| A30076 | Power unit: thermal overload internal braking resistor alarm | S120, S150 |
| A30077 | Power unit: thermal overload internal braking resistor | S120, S150 |
| A30079 | Power unit: referred to the supply voltage, the DC link voltage is too high | S120, S150 |
| A30086 | Power unit: coolant temperature has exceeded the alarm threshold | S120, S150 |
| A30315 | Power unit: 24 V power supply overloaded by PM | G130, G150, S120, S150 |
| A30502 | Power unit: DC link overvoltage | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| A30640 | SI P2: Fault in the switch-off signal path of the second channel | G130, G150, S120, S150 |
| A30666 | SI Motion P2: Steady-state (static) 1 signal at the F-DI for safe acknowledgment | G120, G130, G150, S120, S150 |
| A30693 | SI P2: Safety parameter settings changed, warm restart/POWER ON required | G120, G130, G150, S120, S150 |
| A30772 | SI Motion P2: Test stop for failsafe digital outputs running | G130, G150, S120, S150 |
| A30788 | Automatic test stop: wait for STO deselection via SMM | G120, G130, G150, S120, S150 |
| A30810 | Power unit: Watchdog timer | G120, G120XA, G130, G150, S120, S150 |
| A30853 | Power unit: Sign-of-life error cyclic data | G130, G150, S120, S150 |
| A30919 | Power unit: Temperature monitoring failed | S120, S150 |
| A30920 | Power unit: Temperature sensor fault | G115D, G120, G120C, G120XA, G130, G150, S120, S150 |
| A30930 | Power unit: Component trace has saved data | G130, G150, S120, S150 |
| A30999 | Power unit: Unknown alarm | G120, G130, G150, S120, S150 |