What it means
A30065 reports that the voltage measurement is not supplying any plausible values. Depending on how the drive is configured, the same condition can also be issued as a fault (F) or as a message without an automatic reaction (N). The alarm value stored in r2124 tells you which phase the drive objects to.
Why it appears
- The voltage measurement is not delivering plausible values.
What to check
- Deactivate the voltage measurement: set p0247.0 = 0.
- Deactivate flying restart with voltage measurement: set p0247.5 = 0.
- Deactivate the fast flying restart: set p1780.11 = 0.
- No other remedial action is described for this message.
Reading the message value
- The drive stores the alarm value in r2124; interpret it bitwise binary.
- Bit 1: Phase U.
- Bit 2: Phase V.
- Bit 3: Phase W.
Parameters the manual names
- r2124 — alarm value: read the bits to see which phase (U, V or W) the drive finds implausible.
- p0247 — voltage measurement configuration: set bit 0 = 0 to switch the voltage measurement off and bit 5 = 0 to switch flying restart with voltage measurement off.
- p1780 — motor model adaptation configuration: set bit 11 = 0 to switch the fast flying restart off.
Acknowledging and restarting
As an alarm, A30065 needs no acknowledgment. If the drive's configuration raises the same condition as a fault, the response is still none — the drive does not execute OFF1, OFF2, OFF3 or STOP2 — and the fault must then be acknowledged immediately.
What differs between the drive families
Straight from the manuals' own fields — A30065 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | NONE | NONE | Power electronics faulted (5) | Power Module | SINAMICS S120, S150 List Manual · p. 2962 |
| G130, G150 | NONE | NONE | Power electronics faulted (5) | Power Module | SINAMICS G130, G150 List Manual · p. 1670 |
| G120 | NONE | NONE | Power electronics faulted (5) | — | SINAMICS G120 · p. 916 |
The drives this code lives on
A30065 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does SINAMICS alarm A30065 mean?
It means the voltage measurement is not supplying any plausible values. The alarm value in r2124 shows bitwise which phase — U, V or W — is affected.
How do I acknowledge or reset A30065?
As an alarm it needs no acknowledgment. If the same condition is raised as a fault, the drive performs no automatic stop and the fault is acknowledged immediately.
Which parameters switch off the voltage measurement for A30065?
Set p0247.0 = 0 to deactivate the voltage measurement. To also switch off the related restart functions, set p0247.5 = 0 and p1780.11 = 0.
Can A30065 also appear as a fault?
Yes — depending on the drive's configuration, the same condition can also be issued as a fault (F) or without an automatic reaction (N).