Alarm · SINAMICS G120, G120C, G130, G150, S120, S150

A01666SI Motion P1 (CU): Steady-state (static) 1 signal at the F-DI for safe acknowledgment

What it means

The message SI Motion P1 (CU): Steady-state (static) 1 signal at the F-DI for safe acknowledgment comes from the SI Motion monitoring in the Control Unit (P1). For the safe acknowledgment of internal SI Motion events, the drive uses a failsafe digital input (F-DI) — namely the one configured in p10006. When no acknowledgment is performed at this F-DI for safe acknowledgment, a steady logical 0 signal must be present there. If the F-DI instead stays at logical 1 for more than 10 seconds, the drive raises this alarm.

The monitoring is deliberate: it prevents an unintentional safety-relevant acknowledgment (or the "Internal Event Acknowledge" signal) if a wire breaks or one of the two digital inputs of the F-DI bounces. The manuals also list the same condition with the qualifier F, so depending on the drive's configuration it can additionally be signaled as a fault.

Why it appears

  • The F-DI configured in p10006 for the safe acknowledgment of internal SI Motion events has carried a logical 1 signal for more than 10 seconds.
  • A steady logical 0 signal is required at this F-DI whenever no acknowledgment is performed there for safe acknowledgment; the standing logical 1 violates this.
  • The drive treats the standing 1 as a risk: if a wire breaks or one of the two digital inputs bounces, it could cause an unintentional safety-relevant acknowledgment (or the "Internal Event Acknowledge" signal).

What to check

  1. Identify the F-DI in question: it is the failsafe digital input configured in p10006 for the safe acknowledgment of internal SI Motion events.
  2. Check its signal state: the alarm reports that this input has been at logical 1 for more than 10 seconds, while a steady logical 0 is expected there when no safe acknowledgment is performed.
  3. Carry out the remedy the manual gives: set the failsafe digital input (F-DI) to a logical 0 signal (p10006), i.e. remove the standing logical 1 at that input.

Parameters the manual names

  • p10006 — SI Motion acknowledgment internal event F-DI (processor 1): this parameter selects the failsafe digital input whose signal state is monitored for the safe acknowledgment of internal SI Motion events; it points to the input that must be brought back to a steady logical 0.

Acknowledging and restarting

No acknowledgment is required for this alarm. The fix is at the signal itself: set the failsafe digital input (F-DI) configured in p10006 to a logical 0 signal, so that a steady logical 0 is present whenever no safe acknowledgment is performed there.

What differs between the drive families

Straight from the manuals' own fields — A01666 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEError in the parameterization / configuration / commissioning procedure (18)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2647
G130, G150NONENONEError in the parameterization / configuration / commissioning procedure (18)Control Unit (CU)SINAMICS G130, G150 List Manual · p. 1447
G120NONENONEError in the parameterization / configuration / commissioning procedure (18)SINAMICS G120 · p. 847
G120CSINAMICS G120C Converters · p. 383

The drives this code lives on

A01666 is described for G120, G120C, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A01666 mean?

SI Motion in the Control Unit reports that the failsafe digital input (F-DI) configured in p10006 for safe acknowledgment has carried a logical 1 for more than 10 seconds while no safe acknowledgment was performed at that input.

How do I clear A01666?

Set the F-DI configured in p10006 to a logical 0 signal. A steady logical 0 is what the drive expects at this input whenever no safe acknowledgment takes place there, and no acknowledgment of the alarm itself is needed.

Why does the drive report a static 1 at the F-DI instead of using it?

Because a standing 1 could trigger an unintentional safety-relevant acknowledgment (or the "Internal Event Acknowledge" signal) if a wire breaks or one of the two digital inputs bounces. The alarm makes the steady 1 visible instead.

Can A01666 also appear as a fault?

Yes — the manuals also list the same condition with the qualifier F, so depending on the drive's configuration it can additionally be signaled as a fault.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.