SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Alarm · SINAMICS G130, G150, S120, S150

A07592Encoder 3: Drive Data Set changeover in operation

What it means

A07592 — Encoder 3: Drive Data Set changeover in operation is raised when a Drive Data Set changeover (DDS) was requested while the drive is in operation and that changeover includes a change of the mechanical relationships and of the encoder assignment (p2502). The message relates to encoder 3. Depending on how the drive is configured, the same condition can also be tripped as a fault (F07592) instead of an alarm.

Why it appears

  • A DDS changeover was requested while the drive was in operation, and this changeover involves changing the mechanical relationships and the encoder assignment (p2502).

What to check

  1. Leave the operating state the manual calls "operation" before anything else: To changeover the drive data set, initially, exit the "operation" mode.
  2. Only then carry out the Drive Data Set changeover, including the change of the encoder assignment (p2502).

Parameters the manual names

  • p2502 (LR encoder assignment / encoder assignment): the changeover that triggered the message includes a change of this encoder assignment, so the switch of p2502 belongs to the DDS changeover that must be performed outside of "operation".

Acknowledging and restarting

As an alarm, the message requires no acknowledgement. If the drive is configured to trip the condition as fault F07592 instead, the drive reacts with OFF1 (OFF2, OFF3) and the fault is acknowledged IMMEDIATELY; the changeover should only be repeated after exiting the "operation" mode.

The same on every family

Every manual that describes A07592 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1588
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2854

The drives this code lives on

A07592 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A07592 mean on a SINAMICS drive?

It reports that a Drive Data Set changeover (DDS) for encoder 3 — one that changes the mechanical relationships and the encoder assignment p2502 — was requested while the drive was in operation.

How do I clear A07592?

Exit the "operation" mode first and only then carry out the Drive Data Set changeover. As an alarm it needs no acknowledgement.

Can A07592 also appear as a fault?

Yes — depending on the drive's configuration the same condition can be issued as fault F07592. The drive then reacts with OFF1 (OFF2, OFF3) and the fault is acknowledged IMMEDIATELY.

Which parameter is linked to A07592?

p2502, the (LR) encoder assignment. The message is raised because the requested changeover includes a change of this encoder assignment while the drive is in operation.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A07xxx group · SINAMICS manuals · Siemens manuals