SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Alarm · SINAMICS G130, G150, S120, S150

A07590Encoder 1: Drive Data Set changeover in operation

What it means

A07590 signals that a Drive Data Set changeover (DDS) was requested while the drive was in "operation" mode, and that the data set being selected changes the mechanical relationships together with the encoder assignment of encoder 1 (p2502). A changeover of this scope is not carried out during operation; the drive signals the request with this alarm instead. Depending on the drive configuration, the same condition can also trip as a fault rather than an alarm.

Why it appears

  • A Drive Data Set changeover (DDS) was requested while the drive was in "operation" mode, and the changeover changes the mechanical relationships and the encoder assignment (p2502).

What to check

  1. Exit the "operation" mode: To changeover the drive data set, initially, exit the "operation" mode.
  2. Carry out the Drive Data Set changeover while the drive is outside "operation" mode, so the new mechanical relationships and the encoder assignment p2502 can be applied.

Parameters the manual names

  • p2502 (LR encoder assignment): the alarm applies because the requested DDS changeover includes a change of this encoder assignment alongside the mechanical relationships.

Acknowledging and restarting

As an alarm, A07590 needs no acknowledgment and triggers no automatic stop reaction; it lapses once the changeover is performed outside "operation" mode as the remedy describes. If the drive is configured to raise the same condition as a fault instead, the drive reacts with OFF1 (OFF2, OFF3) and the fault must be acknowledged IMMEDIATELY.

The same on every family

Every manual that describes A07590 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2854
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1588

The drives this code lives on

A07590 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A07590 mean?

It reports that a Drive Data Set (DDS) changeover was requested while the drive was in "operation" mode, and that this changeover changes the mechanical relationships and the encoder assignment (p2502) of encoder 1.

How do I clear A07590?

Exit the "operation" mode and carry out the Drive Data Set changeover there. As an alarm, A07590 requires no acknowledgment.

Does A07590 stop the drive?

As an alarm it triggers no automatic reaction. If the drive is configured to raise the same condition as a fault, it reacts with OFF1 (OFF2, OFF3) and the fault must be acknowledged IMMEDIATELY.

Which parameter is linked to A07590?

p2502, the LR encoder assignment: the alarm is issued when the requested changeover includes a change of this assignment together with the mechanical relationships.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A07xxx group · SINAMICS manuals · Siemens manuals