SINAMICS · 35 codes
SINAMICS F37xxx codes
Code
What the drive shows
Families
F37001
HF Damping Module: overcurrent
S120, S150
F37002
HF Damping Module: Damping voltage too high
S120, S150
F37003
HF Damping Module: Damping voltage not established
S120, S150
F37004
HF Damping Module: Heat sink overtemperature
S120, S150
F37005
HF Damping Module: I2t overload
S120, S150
F37012
HF Damping Module: Heat sink temperature sensor wire breakage
S120, S150
F37013
HF Damping Module: Heat sink temperature sensor short-circuit
S120, S150
F37024
HF Damping Module: Overtemperature thermal model
S120, S150
F37025
HF Damping Module: Chip overtemperature
S120, S150
F37036
HF Damping Module: Internal overtemperature
S120, S150
F37040
HF Damping Module: 24 V undervoltage
S120, S150
F37043
HF Damping Module: 24 V overvoltage
S120, S150
F37045
HF Damping Module: Supply undervoltage
S120, S150
F37052
HF Damping Module: EEPROM data error
S120, S150
F37311
HF Choke Module: Heat sink overtemperature
S120, S150
F37313
HF Choke Module: Overtemperature or fan failure
S120, S150
F37802
HF Damping Module: time slice overflow
S120, S150
F37804
HF Damping Module: CRC
S120, S150
F37820
HF Damping Module: Telegram error
S120, S150
F37835
HF Damping Module: Cyclic data transmission error
S120, S150
F37836
HF Damping Module: Send error for DRIVE-CLiQ data
S120, S150
F37837
HF Damping Module: Component faulted
S120, S150
F37845
HF Damping Module: Cyclic data transmission error
S120, S150
F37850
HF Damping Module: Internal software error
S120, S150
F37851
HF Damping Module (CU): Sign-of-life missing
S120, S150
F37860
HF Damping Module (CU): Telegram error
S120, S150
F37875
HF Damping Module: power supply voltage failed
S120, S150
F37885
HF Damping Module (CU): Cyclic data transmission error
S120, S150
F37886
HF Damping Module (CU): Error when sending DRIVE-CLiQ data
S120, S150
F37887
HF Damping Module (CU): Component faulted
S120, S150
F37895
HF Damping Module (CU): Alternating cyclic data transmission error
S120, S150
F37896
HF Damping Module (CU): Component properties inconsistent
S120, S150
F37899
HF Damping Module: Unknown fault
S120, S150
F37903
HF Damping Module: I2C bus error occurred
S120, S150
F37950
HF Damping Module: Internal software error
S120, S150
All SINAMICS code groups
·
SINAMICS manuals
·
Siemens manuals