Alarm · SINAMICS G130, G150, S120, S150

A33421Encoder 3: Coarse position error

What it means

The manuals give this message two titles: Encoder 3: Coarse position error and Encoder 3: Determined commutation position incorrect (alarm). Both describe the same condition: while sensing the commutation position actual value, the drive detected an error and must therefore assume that the actual value sensing is supplying an incorrect coarse position. Which sensing error occurred is stored as an alarm value in r2124, to be interpreted as a decimal number; for this code the manuals describe alarm value 3. Depending on how the drive is configured, the same condition can also be output as a fault or as a message without a reaction.

Why it appears

  • A commutation position actual value sensing error was detected at Encoder 3, so it must be assumed that the actual value sensing supplies an incorrect coarse position.
  • Alarm value 3: the absolute position of the serial protocol and track A/B differ by half an encoder pulse. The zero position of the absolute position must lie in the quadrants in which both tracks are negative; in the case of a fault, the position can be incorrect by one encoder pulse.

What to check

  1. Read the alarm value in r2124 (interpret it as a decimal number) and confirm that it is 3.
  2. With a standard encoder with cable, contact the encoder manufacturer where relevant.
  3. Correct the assignment of the tracks to the position value that is transferred serially: the two tracks must be connected inverted at the Sensor Module — interchange A with A* and B with B*.
  4. With a programmable encoder, check the zero offset of the position.

Reading the message value

  • The message value %1 is the alarm value; the drive stores it in r2124, to be interpreted as a decimal number. For this code the manuals describe only alarm value 3.
  • 3: The absolute position of the serial protocol and track A/B differ by half an encoder pulse. The absolute position must have its zero position in the quadrants in which both tracks are negative. In the case of a fault, the position can be incorrect by one encoder pulse.

Parameters the manual names

  • r2124 — Alarm value: read here, interpreted as a decimal number, to identify the sensing error behind A33421; value 3 means the absolute position of the serial protocol and track A/B differ by half an encoder pulse.

Acknowledging and restarting

A33421 is an alarm: the drive takes no automatic reaction and the message does not have to be acknowledged. If the drive configuration outputs the same condition as a fault instead, that fault must be acknowledged immediately.

The same on every family

Every manual that describes A33421 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEActual position/speed value incorrect or not available (11)Encoder 3SINAMICS S120, S150 List Manual · p. 3157
G130, G150NONENONEActual position/speed value incorrect or not available (11)Encoder 3SINAMICS G130, G150 List Manual · p. 1829

The drives this code lives on

A33421 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A33421 mean?

The drive detected a commutation position actual value sensing error at Encoder 3 and must assume that the actual value sensing supplies an incorrect coarse position. With alarm value 3 in r2124, the absolute position of the serial protocol and track A/B differ by half an encoder pulse.

How do I fix SINAMICS alarm A33421?

For alarm value 3, contact the encoder manufacturer if a standard encoder with cable is affected, or correct the track assignment: connect the two tracks inverted at the Sensor Module by interchanging A with A* and B with B*. For a programmable encoder, check the zero offset of the position instead.

Does alarm A33421 have to be acknowledged?

No. As an alarm the drive takes no automatic reaction and no acknowledgment is required; only if the same condition is configured as a fault must it be acknowledged immediately.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.