What it means
Alarm A07585 reports that the position actual value of Encoder 2 is currently being set to the value supplied at connector input p2515. This setting is active while the binector input p2514 carries a 1 signal. While it is active, a possible system deviation cannot be corrected. The alarm therefore announces an active position setting rather than a component fault — it tells you that the drive is working with the setting value as the position actual value.
Why it appears
- The binector input p2514 has a 1 signal, so the position actual value of Encoder 2 is set to the value received via connector input p2515.
- While this position setting is active, a possible system deviation cannot be corrected.
What to check
- The manual's remedy for this alarm is:
Not necessary. The alarm is automatically withdrawn with binector input p2514 = 0 signal.
No other check or correction is described for this code.
Parameters the manual names
- p2514 (BI: LR activate position actual value setting) — the binector input whose 1 signal activates the position actual value setting of Encoder 2 and thereby raises A07585; back at the 0 signal, the setting and the alarm end.
- p2515 (CI: LR position actual setting setting value) — the connector input that supplies the position setting value the actual value is set to while p2514 = 1.
Acknowledging and restarting
No acknowledgement is required. The alarm withdraws automatically as soon as binector input p2514 returns to the 0 signal, which ends the setting of the position actual value from p2515.
The same on every family
Every manual that describes A07585 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | NONE | NONE | Application/technological function faulted (17) | Encoder 2 | SINAMICS S120, S150 List Manual · p. 2853 |
| G130, G150 | NONE | NONE | Application/technological function faulted (17) | Encoder 2 | SINAMICS G130, G150 List Manual · p. 1587 |
The drives this code lives on
A07585 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does alarm A07585 mean on a SINAMICS drive?
It reports that the position actual value of Encoder 2 is set to the value supplied at connector input p2515 while binector input p2514 has a 1 signal. While the setting is active, a possible system deviation cannot be corrected.
How do I clear alarm A07585?
No acknowledgement is needed. The alarm disappears automatically as soon as binector input p2514 returns to the 0 signal.
Does A07585 indicate a faulty encoder?
No. The manual states that a remedy is not necessary — the alarm only announces that the position setting via p2515 is active, not an encoder fault.
Which parameters belong to A07585?
p2514 (BI: LR activate position actual value setting) switches the position setting on and off, and p2515 (CI: LR position actual setting setting value) supplies the setting value used while p2514 = 1.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the A07xxx group · SINAMICS manuals · Siemens manuals