What it means
This alarm comes from the trace function. The message text speaks of 2 x 8 recording channels, and the condition behind it is stated plainly: the selected time slice clock cycle cannot be used for more than 4 recording channels. In other words, a trace that is set up to record more than 4 channels is being operated with a time slice clock cycle the drive only permits for up to 4 channels. The alarm points at the trace parameterization — the clock cycle set in p4723 — not at a hardware condition.
Why it appears
- A time slice clock cycle has been selected for the trace (trace time slice cycle, p4723) that cannot be used when more than 4 recording channels are configured; the message text names the 2 x 8 recording channel configuration.
What to check
- Read out the existing time slices and their cycle times with r7901 (sampling times).
- Set a valid clock cycle in p4723: enter the clock cycle of an existing time slice with a cycle time >= 4 ms.
- Alternatively, reduce the number of recording channels to 4 per trace so that the selected clock cycle becomes usable.
Parameters the manual names
- p4723 (trace time slice cycle): the parameter in which the clock cycle of the trace's time slice is entered — here you set a clock cycle that is permissible for the configured number of recording channels, i.e. that of an existing time slice with a cycle time >= 4 ms.
- r7901 (sampling times): read this parameter out to see which time slices exist, and take the clock cycle to enter in p4723 from one of them.
Acknowledging and restarting
No acknowledgement is required, and the drive takes no protective reaction, so no restart step is needed. The alarm is resolved by correcting the trace configuration: once p4723 holds the clock cycle of an existing time slice with a cycle time >= 4 ms, or the trace records at most 4 channels, the condition named by the alarm no longer applies.
What differs between the drive families
Straight from the manuals' own fields — A02059 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS S120, S150 List Manual · p. 2731 |
| G130, G150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS G130, G150 List Manual · p. 1506 |
| G120 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | — | SINAMICS G120 · p. 863 |
The drives this code lives on
A02059 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does alarm A02059 mean on a SINAMICS drive?
It is a trace-function alarm: the selected time slice clock cycle cannot be used for more than 4 recording channels, so a trace configured with more channels (the 2 x 8 configuration) is running with an inadmissible clock cycle.
How do I clear A02059?
Read out the existing time slices with r7901 and enter in p4723 the clock cycle of one with a cycle time >= 4 ms, or reduce the number of recording channels to 4 per trace. No acknowledgement is needed.
Which parameters belong to A02059?
p4723, the trace time slice cycle in which the clock cycle is set, and r7901, which shows the sampling times of the existing time slices.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the A02xxx group · SINAMICS manuals · Siemens manuals