Fault · SINAMICS S120, S150

F06255Infeed: temperature threshold value not permissible

What it means

F06255 is raised by the infeed when at least one configured temperature threshold value lies outside its permissible value range. The thresholds concerned belong to the temperature evaluation of a Voltage Sensing Module (VSM); the fault value shows which module and which threshold pair are affected. Depending on the drive's configuration, the same condition can also be signalled as an alarm.

Why it appears

  • At least one temperature threshold value is set outside the permissible value range.
  • With sensor type KTY84 (p3665 = 2) or PT1000 (p3665 = 6), the value range from 181 °C to 300 °C is not permissible.
  • For the thresholds in p3667/p3668 of a liquid-cooled Active Interface Module (AIM), the value range between 71 °C and 300 °C is also not permissible.

What to check

  1. Read the fault value in r0949 bitwise binary: the bit number corresponds to the number of the Voltage Sensing Module (VSM) involved.
  2. Bit 0 set: check the values in p3667/p3668. With p3665 = 2 (KTY84) or p3665 = 6 (PT1000), values from 181 °C to 300 °C are not permissible; for a liquid-cooled AIM, values between 71 °C and 300 °C are also not permissible.
  3. Bit 1 set: check the value in p5467[0]/p5468[0].
  4. Bit 2 set: check the value in p5467[1]/p5468[1].
  5. Set the temperature thresholds within the measuring range.

Reading the message value

  • The message value is the fault value that the drive stores in r0949; interpret it bitwise binary — the bit number corresponds to the number of the Voltage Sensing Module (VSM) involved.
  • Bit 0: the value in p3667/p3668 is outside the permissible value range. For a liquid-cooled Active Interface Module (AIM), the value range between 71 °C and 300 °C is also not permissible.
  • Bit 1: the value in p5467[0]/p5468[0] is outside the permissible value range.
  • Bit 2: the value in p5467[1]/p5468[1] is outside the permissible value range.

Parameters the manual names

  • p3665 (VSM temperature evaluation sensor type): shows whether KTY84 (= 2) or PT1000 (= 6) is set — for these sensor types the 181 °C to 300 °C range is not permissible.
  • p3667 (VSM overtemperature alarm threshold): bit 0 of the fault value reports this value as outside the permissible range; set it within the measuring range.
  • p3668 (VSM overtemperature shutdown threshold): likewise reported via bit 0; set it within the measuring range.
  • p5467 (VSM2 overtemperature alarm threshold): bits 1 and 2 of the fault value report p5467[0] and p5467[1]; set the affected value within the measuring range.
  • p5468 (VSM2 overtemperature shutdown threshold): likewise reported via bits 1 ([0]) and 2 ([1]); set the affected value within the measuring range.
  • r0949 (fault value): read it bitwise binary to find which VSM and which threshold pair triggered the message.

Acknowledging and restarting

First set the affected thresholds within the permissible range. Then acknowledge the fault immediately; the acknowledgement requires a POWER ON of the drive, after which the infeed can be restarted.

The same on every family

Every manual that describes F06255 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONE (OFF1, OFF2)IMMEDIATELY (POWER ON)Infeed faulted (13)Voltage Sensing Module (VSM)SINAMICS S120, S150 List Manual · p. 2762

The drives this code lives on

F06255 is described for S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F06255 in SINAMICS mean?

The infeed reports that at least one temperature threshold value is set outside its permissible value range. The fault value in r0949 shows bitwise which Voltage Sensing Module and which threshold pair are affected.

Which parameters trigger F06255?

The thresholds in p3667/p3668 (bit 0), p5467[0]/p5468[0] (bit 1) and p5467[1]/p5468[1] (bit 2). The sensor type set in p3665 decides which value ranges are permissible.

Which temperature range is not permissible for KTY84 or PT1000?

With sensor type KTY84 (p3665 = 2) or PT1000 (p3665 = 6), thresholds from 181 °C to 300 °C are not permissible. For a liquid-cooled AIM, the range between 71 °C and 300 °C is also not permissible for p3667/p3668.

How do I reset fault F06255?

Set the temperature thresholds within the measuring range, then acknowledge the fault immediately. The acknowledgement requires a POWER ON of the drive, after which the infeed can be restarted.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F06xxx group · SINAMICS manuals · Siemens manuals