What it means
A06105 is an infeed alarm for line supply undervoltage. The drive continuously evaluates the filtered (steady-state) value of the line supply voltage and raises this message when that value drops below the product of the alarm threshold p0282 and the set line supply voltage p0210. The alarm value that accompanies the message is the actual steady-state line supply voltage; the drive holds it in r2124 as a floating-point number. Depending on how the drive is configured, the same condition can also be output as a fault instead of an alarm.
Why it appears
- The filtered (steady-state) value of the line supply voltage is lower than the alarm threshold: the drive raises the message when the filtered steady-state line supply voltage falls below the product of the alarm threshold p0282 and the set line supply voltage p0210.
What to check
- Check the line supply.
- Check the line supply voltage: confirm that the value set in p0210 (drive unit line supply voltage) matches the voltage actually connected to the unit.
- Check the alarm threshold p0282 (line supply undervoltage alarm threshold).
Reading the message value
- The message value appears as %1.
- The alarm value is stored in r2124 (floating point) and contains the actual steady-state line supply voltage — the value that fell below the threshold.
Parameters the manual names
- p0282 — Line supply undervoltage alarm threshold: the threshold against which the filtered line supply voltage is compared for this alarm; check it when A06105 appears.
- p0210 — Drive unit line supply voltage: the set line supply voltage that enters the comparison (p0282 × p0210); check that it matches the connected supply.
- r2124 — Alarm value: read here, as a floating-point value, the actual steady-state line supply voltage that triggered the alarm.
Acknowledging and restarting
As an alarm, the message signals the undervoltage condition without an automatic shutdown and does not need to be acknowledged. If the drive configuration outputs the same condition as a fault instead, the fault reaction is NONE — the drive does not perform OFF1 or OFF2 on its own; OFF1 and OFF2 are the alternative reactions that can be configured. In the fault case the message is acknowledged IMMEDIATELY; POWER ON is the alternative acknowledgment setting.
What differs between the drive families
Straight from the manuals' own fields — A06105 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | — | — | Network fault (2) | None | SINAMICS S120, S150 List Manual · p. 2756 |
| G130, G150 | NONE | NONE | Network fault (2) | None | SINAMICS G130, G150 List Manual · p. 1528 |
The drives this code lives on
A06105 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does SINAMICS alarm A06105 mean?
It means the infeed detected line supply undervoltage: the filtered (steady-state) line supply voltage is below the alarm threshold, i.e. below p0282 × p0210. The alarm value in r2124 shows the actual steady-state line supply voltage.
How do I clear A06105?
Check the line supply, then check that the line supply voltage set in p0210 matches the connected supply, and check the alarm threshold p0282. As an alarm the message needs no acknowledgment; if it is output as a fault, it is acknowledged IMMEDIATELY (alternative: POWER ON).
Why does A06105 appear even though the correct supply is connected?
The comparison uses the settings as well as the actual grid: the drive raises the message when the filtered steady-state voltage falls below p0282 multiplied by p0210. Check both parameters against the voltage really connected.
Is A06105 a fault or an alarm?
It appears as an alarm; depending on the drive configuration, the same condition can also be output as a fault.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the A06xxx group · SINAMICS manuals · Siemens manuals