What it means
F07484 belongs to the EPOS function and concerns the fixed stop. When the drive is in the 'fixed stop reached' state, it watches the axis position against the monitoring window configured in p2635. If the axis moves outside this window, the drive raises fault F07484. The manuals that describe this fault, for the G130, G150, S120 and S150, give an identical cause and remedy.
Why it appears
- While the drive was holding the axis at the fixed stop in the 'fixed stop reached' state, the axis moved out of the monitoring window set in p2635.
What to check
- Check the fixed stop monitoring window configured in p2635.
- Check the mechanical system.
Parameters the manual names
- p2635 — EPOS fixed stop monitoring window: the window the axis must stay within once the fixed stop has been reached; check its setting when F07484 occurs.
Acknowledging and restarting
Acknowledge the fault as soon as it has been detected. Once the cause has been removed and the fault has been acknowledged, the drive can be started again.
The same on every family
Every manual that describes F07484 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | OFF3 (OFF1, OFF2) | IMMEDIATELY | Application/technological function faulted (17) | None | SINAMICS S120, S150 List Manual · p. 2827 |
| G130, G150 | OFF3 (OFF1, OFF2) | IMMEDIATELY | Application/technological function faulted (17) | None | SINAMICS G130, G150 List Manual · p. 1564 |
The drives this code lives on
F07484 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does fault F07484 in SINAMICS mean?
It is an EPOS fixed stop fault: while the drive was in the 'fixed stop reached' state, the axis moved outside the monitoring window set in p2635.
Which parameter belongs to F07484?
p2635, the EPOS fixed stop monitoring window. Check its setting, and also check the mechanical system, to clear the fault.
Which converters raise F07484?
The fault is described for G130, G150, S120 and S150, and the manuals give the same cause and remedy for all of them.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the F07xxx group · SINAMICS manuals · Siemens manuals
