F06080Infeed: parameter error

What it means

F06080 (Infeed: parameter error) is output by an infeed of a SINAMICS S120 or S150 when one of the infeed's parameters is incorrectly set. The drive writes the number of the affected parameter into the fault value r0949, so the message itself pinpoints the setting that has to be corrected. The infeed is tripped and the fault must be acknowledged before the drive can run again. Depending on the drive configuration, the same condition can also be signalled as an alarm (A06080).

Why it appears

  • An infeed parameter is set incorrectly; the fault value names the parameter concerned.

What to check

  1. Read the fault value in r0949 and interpret it as a decimal number — it contains the number of the parameter that is incorrectly set. The message value displays the same information as "Parameter: %1".
  2. Open the parameter named by the fault value and change it to the appropriate value. The manual cross-references p0220, p3665, p3667 and p3668 for this fault, so these are the settings to review if the fault value points to one of them.
  3. Acknowledge the fault immediately after correcting the parameter; depending on the configuration, the drive only accepts the acknowledgement after a POWER ON.

Reading the message value

  • r0949, interpreted as a decimal number: contains the number of the parameter involved.
  • Message value "Parameter: %1": the drive replaces %1 with the number of the incorrectly set parameter.

Parameters the manual names

  • r0949 — fault value: read it as a decimal number to identify the parameter that triggered F06080.
  • p0220 — hydraulic oil modulus of elasticity: named by the manual for this fault; correct its setting if the fault value points to it.
  • p3665 — VSM temperature evaluation sensor type: also named for this fault; correct it if the fault value refers to it.
  • p3667 — VSM overtemperature alarm threshold: also named for this fault; reset it to the appropriate value if it is the one indicated.
  • p3668 — VSM overtemperature shutdown threshold: also named for this fault; correct it when the fault value names it.

Acknowledging and restarting

First correct the parameter named in the fault value, then acknowledge the message — the manual specifies immediate acknowledgement, and depending on the configuration the drive accepts it only after a POWER ON. When the condition is output as an alarm (A06080), the manual specifies no reaction and no acknowledgement. Once the fault has been acknowledged, the drive can be started again.

The same on every family

Every manual that describes F06080 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150OFF2 (NONE, OFF1)IMMEDIATELY (POWER ON)Infeed faulted (13)Power ModuleSINAMICS S120, S150 List Manual · p. 2756

The drives this code lives on

F06080 is described for S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F06080 mean on a SINAMICS infeed?

It reports "Infeed: parameter error" — an infeed parameter is incorrectly set. The fault value in r0949, read as a decimal number, is the number of the parameter involved.

How do I find and fix the parameter behind F06080?

Read r0949 as a decimal number to get the parameter number, then change that parameter to the appropriate value. The manual also names p0220, p3665, p3667 and p3668 in connection with this fault.

How is F06080 acknowledged?

Immediately after correcting the parameter; depending on the configuration the drive only accepts the acknowledgement after a POWER ON. When the condition appears as alarm A06080, no acknowledgement is required.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F06xxx group · SINAMICS manuals · Siemens manuals