What it means
The firmware of the power unit does not support filter temperature evaluation. This feature, which appears as r0192.11 in the power unit firmware properties, becomes a requirement as soon as an Active Interface Module is used as a line filter — the drive recognizes that configuration from p0220 = 41 ... 45. Firmware and configuration therefore do not match, and the drive coasts down and must be acknowledged before it will start.
Why it appears
- The power unit firmware does not support filter temperature evaluation.
- The configuration nevertheless requires this feature: an Active Interface Module is in use as a line filter (p0220 = 41 ... 45), and for this configuration filter temperature evaluation (r0192.11) is mandatory.
What to check
- Read p0220: a value of 41 ... 45 confirms that an Active Interface Module is used as a line filter, i.e. the configuration that demands filter temperature evaluation.
- Check r0192 (Power unit firmware properties 1): r0192.11 tells you whether the power unit firmware actually provides the filter temperature evaluation feature.
- Upgrade the firmware of the power unit to a later version, then acknowledge the fault.
Parameters the manual names
- r0192 (Power unit firmware properties 1): r0192.11 represents the filter temperature evaluation feature of the power unit — read it to verify whether the firmware supports what the line filter configuration requires.
- p0220 (Hydraulic oil modulus of elasticity): in this fault, the setting 41 ... 45 is what marks an Active Interface Module as the line filter and makes filter temperature evaluation (r0192.11) mandatory.
Acknowledging and restarting
The drive coasts down and will only start again once the fault has been acknowledged. Acknowledging alone does not remove the cause, though: the fault only stays away after the power unit firmware has been upgraded to a later version.
The same on every family
Every manual that describes F06052 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | OFF2 (NONE) | IMMEDIATELY | Error in the parameterization / configuration / commissioning procedure (18) | Power Module | SINAMICS S120, S150 List Manual · p. 2756 |
The drives this code lives on
F06052 is described for S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does fault F06052 mean in SINAMICS?
The power unit firmware does not support filter temperature evaluation (r0192.11), although this feature is required because an Active Interface Module is used as a line filter (p0220 = 41 ... 45).
How do I fix fault F06052?
Upgrade the firmware of the power unit to a later version. r0192 (Power unit firmware properties 1) shows whether the filter temperature evaluation feature is present.
Why does F06052 appear with an Active Interface Module?
Filter temperature evaluation is required when an Active Interface Module is used as a line filter, which the drive recognizes from p0220 = 41 ... 45.
Which parameters belong to F06052?
r0192, whose bit r0192.11 stands for the feature, and p0220, whose value 41 ... 45 marks the Active Interface Module as line filter.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the F06xxx group · SINAMICS manuals · Siemens manuals