Alarm · SINAMICS G130, G150, S120, S150

A07505EPOS: Task fixed stop not possible in the U/f/SLVC mode

What it means

A07505 appears when an EPOS traversing block with the "fixed stop" task is to be executed while the drive is in the U/f/SLVC mode. This combination is not possible: the traversing block task "fixed stop" cannot be carried out in this operating mode. The alarm value identifies the traversing block concerned.

Why it appears

  • A traversing block with the "fixed stop" task was to be executed while the drive was in the U/f/SLVC mode; this task cannot be executed in that mode.

What to check

  1. Read the alarm value in r2124 as a decimal number — it gives the number of the traversing block with the illegal task parameter.
  2. Check this traversing block and change the task set in it (p2621).
  3. If the "fixed stop" task is nevertheless required, change the open-loop/closed-loop control operating mode (p1300), because the task cannot be executed in the U/f/SLVC mode.

Reading the message value

  • The drive enters the alarm value in r2124; interpret it as a decimal number.
  • It contains the number of the traversing block with an illegal task parameter.

Parameters the manual names

  • r2124 — alarm value; read it as a decimal number to identify the traversing block whose task parameter is illegal.
  • p2621 — EPOS traversing block task; the task of the affected traversing block is set here and must be changed.
  • p1300 — open-loop/closed-loop control operating mode; change this mode if the "fixed stop" task is to be used.

Acknowledging and restarting

This alarm requires no acknowledgement. It is resolved by removing the cause: change the task of the traversing block named in r2124 or change the operating mode in p1300 so that the "fixed stop" task is no longer executed in the U/f/SLVC mode.

The same on every family

Every manual that describes A07505 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2834
G130, G150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1571

The drives this code lives on

A07505 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A07505 mean on a SINAMICS drive?

An EPOS traversing block with the "fixed stop" task was to be executed while the drive was in the U/f/SLVC mode; this task is not possible there.

How do I find the traversing block that triggers A07505?

Read the alarm value in r2124 as a decimal number — it is the number of the traversing block with the illegal task parameter.

How do I clear alarm A07505?

Check the traversing block and change its task (p2621), or change the open-loop/closed-loop control operating mode (p1300) if the fixed stop task is required.

Does A07505 have to be acknowledged?

No. The alarm requires no acknowledgement; it is resolved by correcting the traversing block task or the operating mode.