Alarm · SINAMICS G130, G150, S120, S150

A07497LR: Position setting value activated

What it means

A07497 is an alarm that reports the active LR position actual value setting: while the binector input p2514 carries a 1 signal, the position actual value is set to the value received via connector input p2515. The drive raises the alarm so this state is visible, because while the setting is active a possible system deviation cannot be corrected. Depending on the drive's configuration, the condition can also be issued with no reaction (N).

Why it appears

  • The binector input p2514 carries a 1 signal, so the position actual value is set to the value received via connector input p2515.
  • While the setting is active, a possible system deviation cannot be corrected.

What to check

  1. No measures are necessary — the alarm only reports that the setting function is active.
  2. If the position actual value should not be set, return the binector input p2514 to the 0 signal; the alarm then disappears automatically.

Parameters the manual names

  • p2514 — binector input that activates the LR position actual value setting; the alarm is present while it is 1 and withdraws automatically when it returns to 0.
  • p2515 — connector input supplying the value that the position actual value is set to while p2514 = 1.

Acknowledging and restarting

No acknowledgement is required. The alarm withdraws itself automatically as soon as the binector input p2514 returns to the 0 signal.

The same on every family

Every manual that describes A07497 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2831
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1568

The drives this code lives on

A07497 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A07497 mean on SINAMICS?

It reports that the LR position actual value setting is active: while binector input p2514 = 1, the position actual value is set to the value received via connector input p2515. A possible system deviation cannot be corrected while this is active.

How do I clear alarm A07497?

No acknowledgement is needed. The alarm disappears automatically as soon as the binector input p2514 returns to the 0 signal.

Is A07497 a drive fault?

No — the manuals list it as an alarm for which no remedy is necessary; it only reports the active setting function. Depending on the drive's configuration it can also be issued with no reaction (N).

Why can no system deviation be corrected?

Because while p2514 = 1 the position actual value is set to the value at p2515, and in this state a possible system deviation cannot be corrected.