Alarm · SINAMICS G130, G150, S120, S150

A07487EPOS: Reject traversing task missing

What it means

This alarm belongs to the EPOS positioning function. In the modes “traversing blocks” and “direct setpoint input/MDI”, the drive expects a 1 signal at the binector input “do not reject traversing task/reject traversing task” (BI: p2641) when a motion starts. The 1 signal tells the drive not to reject the traversing task; if it is missing at the start of motion, the drive raises A07487. The manuals describe the condition identically for every affected drive object, so the same explanation applies across the families.

Why it appears

  • In the modes “traversing blocks” or “direct setpoint input/MDI”, the binector input “do not reject traversing task/reject traversing task” (BI: p2641) does not have a 1 signal at the start of motion.

What to check

  1. Connect a 1 signal to the binector input “do not reject traversing task/reject traversing task” (BI: p2641).
  2. Restart the motion.

Parameters the manual names

  • p2641 — BI: EPOS reject traversing task (0 signal) / Trav_task reject: the binector input that must carry the 1 signal when motion starts in “traversing blocks” or “direct setpoint input/MDI” mode.

Acknowledging and restarting

No acknowledgement is required for this alarm. Once a 1 signal is connected to the binector input (BI: p2641) and the motion is restarted, the condition named in the remedy is resolved.

The same on every family

Every manual that describes A07487 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2828
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1565

The drives this code lives on

A07487 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A07487 mean on a SINAMICS drive?

It belongs to the EPOS positioning function: at the start of motion in “traversing blocks” or “direct setpoint input/MDI” mode, the binector input “do not reject traversing task/reject traversing task” (BI: p2641) does not have a 1 signal.

How do I clear alarm A07487?

Connect a 1 signal to the binector input (BI: p2641) and restart the motion. The alarm does not have to be acknowledged.

Which parameter is involved in A07487?

p2641 — BI: EPOS reject traversing task (0 signal) / Trav_task reject. This is the input that must receive the 1 signal before the motion starts.