SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Alarm · SINAMICS G130, G150, S120, S150

A07455EPOS: Maximum velocity limited

What it means

A07455 is an alarm from the EPOS positioning function. It is raised when the set maximum velocity p2571 is too high to calculate the modulo correction correctly. For a correct modulo correction, traveling at the maximum velocity for one positioning sampling time (p0115[5]) must cover at most the half modulo length. Because the set p2571 exceeded this, the drive limited p2571 to the permissible value, and the alarm reports this limiting.

Why it appears

  • The maximum velocity p2571 is set too high to correctly calculate the modulo correction.
  • Within the sampling time for positioning (p0115[5]), moving at the maximum velocity would cover more than the half modulo length.
  • The drive has limited p2571 to this permissible value.

What to check

  1. Reduce the maximum velocity (p2571).
  2. Alternatively, or in addition, increase the sampling time for positioning (p0115[5]), so that the half modulo length is not exceeded within one sampling interval even at maximum velocity.

Parameters the manual names

  • p2571 — EPOS maximum velocity (v_max): the value that is too high here and that the drive has limited; reducing it is the first remedy for this alarm.
  • p0115[5] — sampling time for positioning (p0115 holds the sampling times for the supplementary functions): increasing it is the second remedy, because it raises the travel permitted per interval before the half modulo length is reached.

Acknowledging and restarting

No acknowledgement is required for this alarm, and the drive does not interrupt operation because of it. The alarm is dealt with through the parameterization itself: reduce p2571 or increase p0115[5] as described above.

The same on every family

Every manual that describes A07455 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2820
G130, G150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1557

The drives this code lives on

A07455 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A07455 mean?

It is reported by the EPOS function when the set maximum velocity p2571 is too high to calculate the modulo correction correctly. The drive has limited p2571 to the highest permissible value.

How do I clear A07455?

Reduce the maximum velocity p2571 or increase the sampling time for positioning p0115[5]. The condition is that, within one positioning sampling interval at maximum velocity, at most the half modulo length is moved through.

Does A07455 have to be acknowledged?

No acknowledgement is required, and the drive does not interrupt operation because of this alarm. It is resolved by correcting p2571 or p0115[5].

Which sampling time does A07455 refer to?

Index [5] of p0115, the sampling time for positioning among the supplementary-function sampling times held in p0115.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A07xxx group · SINAMICS manuals · Siemens manuals