What it means
A07462 is an alarm from the EPOS functions: the traversing block that was just started does not exist in the drive. A block number is selected at the binector inputs p2625 ... p2630 (selection bits 0 to 5), and the traversing task is started with the 0/1 edge of binector input p2631 "Activate traversing task". If the number selected in this way is not available — because it is not contained in p2616[0...n] or because the started traversing block is suppressed — the drive raises this alarm. It points to the traversing program parameterization; the drive takes no automatic action in response, and no acknowledgement is needed.
Why it appears
- A traversing block was selected via binector input p2625 ... p2630 and was started via binector input p2631 with the 0/1 edge "Activate traversing task", and the number of the started traversing block is not contained in p2616[0...n].
- The started traversing block is suppressed.
What to check
- Read the alarm value in r2124 and interpret it as a decimal number: it contains the number of the selected traversing block that is not available.
- Check whether this number is contained in p2616[0...n]; if it is missing there, the started traversing block does not exist.
- Check whether the started traversing block is suppressed.
- Correct the traversing program and select an available traversing block number.
Reading the message value
- The drive stores the alarm value in r2124; interpret the value as a decimal number.
- The value is the number of the selected traversing block that is also not available.
Parameters the manual names
- p2625 ... p2630 — binector inputs "EPOS traversing block selection" bit 0 to bit 5; their signal state selects the number of the traversing block that is started.
- p2631 — binector input "EPOS activate traversing task (0 -> 1)"; the 0/1 edge of this input starts the selected traversing task.
- p2616[0...n] — "EPOS traversing block block number"; the numbers of the existing traversing blocks are entered here, and the number of the started block must be contained in this list.
- r2124 — alarm value; read it as a decimal number to identify the traversing block number that is not available.
Acknowledging and restarting
No acknowledgement is required for this alarm. Correct the traversing program and select an available traversing block number, so that the block started via p2631 is contained in p2616[0...n] and is not suppressed.
The same on every family
Every manual that describes A07462 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS S120, S150 List Manual · p. 2822 |
| G130, G150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS G130, G150 List Manual · p. 1559 |
The drives this code lives on
A07462 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does alarm A07462 mean in SINAMICS?
It is an EPOS alarm: the traversing block started via p2631 does not exist, because its number is not contained in p2616[0...n] or the started traversing block is suppressed.
How do I find out which traversing block triggered A07462?
Read the alarm value in r2124 and interpret it as a decimal number — it is the number of the selected traversing block that is not available.
Does A07462 have to be acknowledged?
No. Correct the traversing program and select an available traversing block number; no acknowledgement of the alarm is required.
Which signals select and start the traversing block behind A07462?
The block number is selected via the binector inputs p2625 ... p2630 (selection bits 0 to 5), and the task is started with the 0/1 edge of p2631 "Activate traversing task".
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.