What it means
A07092 is the alarm Drive: moment of inertia estimator still not ready
. It appears while the drive's moment of inertia estimator is still working: the estimator has not yet determined any valid values, and therefore the acceleration cannot be calculated. The alarm is described for the G120, G130, G150, S120 and S150. The estimator counts as stabilized once the frictional values (p1563, p1564) and the moment of inertia value (p1493) have been determined and the status signal r1407.26 is set to 1. No acknowledgment is required — the alarm withdraws itself once the estimator has stabilized.
Why it appears
- The moment of inertia estimator has still not determined any valid values, so the acceleration cannot be calculated — the estimator is simply not yet stabilized.
- The response of the moment of inertia estimator is influenced by the parameters p1560, p1561 and p1562.
What to check
- Traverse the axis until the moment of inertia estimator has stabilized.
- Use the status signal r1407.26 to see when this point is reached: it equals 1 once the frictional values (p1563, p1564) and the moment of inertia value (p1493) have been determined.
- After stabilization the alarm withdraws itself, so no reset is needed. For the G120 the remedy is worded slightly differently:
Repeat the operation when the moment of inertia estimator is ready (r1407.26 = 1)
.
Parameters the manual names
- p1560 — moment of inertia estimator accelerating force threshold value (J_est F thr); named by the manual as one of the parameters that influence the response of the estimator.
- p1561 — inertia estimator change time high inertia mass (J_est t_chg M); likewise influences the response of the estimator.
- p1562 — moment of inertia estimator change time load (J_est t load); likewise influences the response of the estimator.
- p1563 — CO: moment of inertia estimator load force positive direction (J_est F pos); this frictional value must be determined before the estimator counts as stabilized.
- p1564 — CO: moment of inertia estimator load force negative direction (J_est F neg); this frictional value must be determined before the estimator counts as stabilized.
Acknowledging and restarting
No acknowledgment is needed. The alarm is withdrawn automatically as soon as the moment of inertia estimator has stabilized, i.e. once the frictional values (p1563, p1564) and the moment of inertia value (p1493) have been determined and r1407.26 = 1. Until then the axis has to be traversed so that the estimator can determine its values.
What differs between the drive families
Straight from the manuals' own fields — A07092 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | Control Unit (CU) | SINAMICS S120, S150 List Manual · p. 2786 |
| G130, G150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | Control Unit (CU) | SINAMICS G130, G150 List Manual · p. 1539 |
| G120 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | — | SINAMICS G120 · p. 874 |
The drives this code lives on
A07092 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does A07092 mean on a SINAMICS drive?
It is the alarm 'Drive: moment of inertia estimator still not ready': the estimator has not yet determined any valid values, so the acceleration cannot be calculated.
How do I get rid of alarm A07092?
Traverse the axis until the moment of inertia estimator has stabilized. The alarm then withdraws itself automatically — no acknowledgment is required.
How do I know when the moment of inertia estimator is ready?
When the frictional values (p1563, p1564) and the moment of inertia value (p1493) have been determined and the status signal r1407.26 equals 1.
Which parameters influence the moment of inertia estimator?
p1560 (accelerating force threshold value), p1561 (change time high inertia mass) and p1562 (change time load) influence the response of the estimator.