TR10-F 1
TR10-F
On order
WIKA · Temperature measurement · Family TR10

Flanged resistance thermometer

Flanged resistance thermometer with protection tube, suitable for liquid and gaseous media under moderate mechanical load, with replaceable measuring insert and optional explosion protection.
Range
-196…600 °C
Output
4-20mA · HART
Protection
IP65
CERoHSATEXIECExEACEx UkraineINMETROCCCKCs-KOSHAPESOGOSTMTSCHSBelGIMUkrSEPROUzstandardKazInMetrEMCNAMUR NE 024KazlnMetrII 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbII 2G Ex eb IIC T1 ... T6 GbII 3G Ex ec IIC T1 ... T6 Gc XII 2D Ex tb IIIC TX °C Db0Ex ia IIC T6 ... T1 Ga X1Ex ia IIC T6 ... T1 Gb X2Ex nA IIC T6 ... T1 Gc XEx iaD 20 T65/T95/T125°CII 3D Ex tc IIIC TX °C Dc XII 3G Ex nA IIC T1 ... T6 Gc XEx ia IIIC T80…T440 °C Da XEx ia IIC T3 ... T6 GaEx nA IIC T1 ~ T6 GcEx ia IIC T4 ... T6Ex ib IIC T4 ... T6Ex ia IIIC T125 ...T65 °C Db0Ex ia IIC T6 ...T1 Ga X2Ex nA IIC T6 ...T1 Gc XEx ia IIC T3 ...T6 GaEx ia IIC T1 ~ T6 Ga/GbEx ic IIC T1 ~ T6 GcEx iaD 21 T65/T95/T125°CEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Ga/GbEx ia IIIC T80...T440 °C Da XEx ia IIIC T80...T440 °C Db XExiaIICT3...T6GaExiaIICT3...T6Ga/GbT65℃DaExiaIICT125...T65℃Da/DbExiaIICT1 ~~ T6GaExiaIICT1~~ T6GbExiaIICT1 ~~ T6Ga/GbExicIICT1~~ T6GcExiaD20T65/T95/T125℃ExiaD21T65/T95/T125℃ExiaD20/21T65/T95/T125℃ExnAIICT1~T6GcExiaIICT4...T6ExibIICT4...T6
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Resistance thermometers of this series are designed for fitting into vessels and pipelines. Standard flanges to DIN EN or ASME are available.

These temperature sensors are suitable for liquid and gaseous media under moderate mechanical load. The protection tube is all welded and screwed into the connection head. Stainless steel protection tubes are suitable for normal chemical conditions. Coating is recommended as an optional extra with chemically aggressive media, or solid wear-resistant coating for abrasive media.

The interchangeable measuring insert can be removed without taking out the complete sensor from the plant. This enables inspection, measuring equipment monitoring or, when servicing is necessary, replacement while the plant is running. The choice of standard lengths assists with short delivery times and the possibility of stocking spare parts.

Special features

  • Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
  • With integrated fabricated protection tube
  • Spring-loaded measuring insert (replaceable)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)
Configurator · Step by step

Build a TR10-F for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 3
Configuration structure· click a highlighted segment to jump to that parameter
Your configuration
  • Electrical approvalWithout
  • Ignition protection typeWithout
  • ZoneWithout
  • Sensor1xPt100, 3-wire
  • Accuracy class of the sensorClass B, IEC 60751
  • Temperature range of selected class-50...+250°C
  • Head / housingBSZ, Aluminum, ball shaped, flip-top
  • Cable entryStandard cable gland for für A-/B-/J- heads
  • Thread size cable entryM20 x 1.5
  • TransmitterWithout (terminal block)
  • Transmitter detailsWithout
  • Connection to neck tubeM24 x 1,5
  • Protection tubeStraight, flange, form 2F DIN 43772
  • Protection tube materialStainless steel 1.4571
  • Protection tube diameter9x1 mm
  • Flange sizeEN 1092-1 DN 25
  • Pressure rating—
  • Flange face—
  • Insertion length [A]—
  • Neck length [MH/N]65
  • Mechanical requirementsWithout
  • Thermowell specialsWithout
  • CertificatesWithout