Bimetal thermometer
Description
The model TG54 bimetal thermometer has been developed and is manufactured in accordance with the EN 13190 standard. The thermometer meets the high requirements of the process industries.
Especially in the chemical and petrochemical, oil and gas, power engineering and shipbuilding industries, the temperature measuring instrument manufactured from stainless steel is used successfully. The robust, hermetically sealed case with IP65 ingress protection enables use with harsh external conditions and high vibration.
For further approvals see page 9
Fig. left: Back mount (axial)
Fig. right: Back mount, adjustable stem and dial
With a count of four different nominal sizes, an optimal matching to the available space and mounting conditions is possible.
At an easily accessible point on the back of the case, the zero point can be easily corrected.
The model TG54 meets the high requirements for resistance against aggressive media. As an option, the case, the stem and the process connection can be made from 316L.
Special features
- Nominal sizes 63, 80, 100, 160 mm [2.5, 3, 4, 6"]
- Robust, hermetically sealed case
- External reset for setting the reference temperature
- Dished dial (anti-parallax) for ease of reading
- Adjustable stem and dial version enables optimal process connection
| Model | TG54 |
| Product family | TG |
| Subcategory | Process bimetal thermometer |
| Temperature ranges | −70…+70 °C · −70…+30 °C · −60…+50 °C · −50…+50 °C · −50…+100 °C · −50…+200 °C · −50…+300 °C · −50…+400 °C · −50…+500 °C · −40…+40 °C · −40…+60 °C · −40…+80 °C · −40…+160 °C · −30…+30 °C · −30…+50 °C · −30…+70 °C · −20…+40 °C · −20…+60 °C · −20…+80 °C · −20…+100 °C · −20…+120 °C · −20…+140 °C · −10…+50 °C · +0…+60 °C · +0…+80 °C · +0…+100 °C · +0…+120 °C · +0…+160 °C · +0…+200 °C · +0…+250 °C · +0…+300 °C · +0…+400 °C · +0…+500 °C · +0…+600 °C |
| Accuracy class | Class 1 |
| Process connection | G ½ B½ NPTM20 x 1.5M24 x 1.5G ½ B female½ NPT femaleM24 x 1.5 female |
| Process temperature | −50…+600 °C |
| Probe material | Stainless steel 304, Stainless steel 316 |
| Thermowell material | Stainless steel 304, Stainless steel 316 |
| Ambient temperature | −50…+70 °C |
| IP rating | IP65 |
| Certifications | CERoHS |
| Explosion protection | II 2G Ex h IIC T6 ... T1 Gb XII 2D Ex h IIIC T85 ... T450 °C Db X |
| Sensor type | bimetal |
| Sensor class | Class 1 |
| Probe length | 1000 mm |
| Probe diameter | 6 mm |
| Thermowell | No |
| Thermowell form | Form 4.1 |
| Datasheet languages | EN, DE |
| Basic information | |
|---|---|
| Standard | EN 13190 |
| Nominal size | ■ 63 mm[2.5 " ] ■ 80 mm[3 " ] ■ 100 mm[4 " ] ■ 160 mm[6 " ] |
| Window | ■ Instrument glass ■ Laminated safety glass ■ Polycarbonate (shatterproof) |
| Connection location | ■ Back mount (axial) ■ Lower mount (radial) ■ Back mount, adjustable stem and dial |
| Connection design | →For drawings, see page 10 |
| S | Standard (male threaded connection) |
| 1 | Plain stem (without thread) |
| 2 | Male nut |
| 3 | Union nut |
| 4 | Compression fitting (sliding on stem) |
| 4.1 | Compression fitting with support tube sliding on stem |
| Versions | ■ Standard version ■ Oil- and grease-free version ■ Silicone-oil-less version |
| Dampening, case filling | ■ Without ■ With silicone oil case filling, up to max. 250 °C [482 °F] (at the probe) |
| Material (in contact with the environment) | |
| Case, ring | ■ Stainless steel 304 ■ Stainless steel 316 |
| Elbow behind the case (only with lower mount) | ■ Stainless steel 304 ■ Stainless steel 316 |
| Scale range in °C | Measuring range 1) in °C | Scale interval in °C |
|---|---|---|
| -70 ... +70 | -50 ...+50 | 2 |
| -70 ... +30 | -60 ...+20 | 1 |
| -60 ... +50 | -50 ...+40 | 1 |
| -50 ... +50 | -40 ...+40 | 1 |
| -50 ... +100 | -30 ...+80 | 2 |
| -50 ... +200 | -20 ...+170 | 5 |
| -50 ... +300 | 0 ... 250 | 5 |
| -50 ... +400 | 0 ... 350 | 5 |
| -50 ... +500 | 0 ... 450 | 10 |
| -40 ... +40 | -30 ...+30 | 1 |
| -40 ... +60 | -30 ...+50 | 1 |
| -40 ... +80 | -20 ...+60 | 2 |
| -40 ... +160 | -20 ...+140 | 2 |
| -30 ... +30 | -20 ...+20 | 1 |
| -30 ... +50 | -20 ...+40 | 1 |
| -30 ... +70 | -20 ...+60 | 1 |
| -20 ... +40 | -10 ...+30 | 1 |
| -20 ... +60 | -10 ...+50 | 1 |
| -20 ... +80 | -10 ...+70 | 1 |
| -20 ... +100 | 0 ... 80 | 2 |
| -20 ... +120 | 0 ... 100 | 2 |
| -20 ... +140 | 0 ... 120 | 2 |
| -10 ... +50 | 0 ... 40 | 1 |
| 0 ... 60 | 10 ... 50 | 1 |
| 0 ... 80 | 10 ... 70 | 1 |
| 0 ... 100 | 10 ... 90 | 1 |
| 0 ... 120 | 10 ... 110 | 2 |
| 0 ... 160 | 20 ... 140 | 2 |
| 0 ... 200 | 20 ... 180 | 2 |
| 0 ... 250 | 30 ... 220 | 5 |
| 0 ... 300 | 30 ... 270 | 5 |
| 0 ... 400 | 50 ... 350 | 5 |
| 0 ... 500 | 50 ... 450 | 5 |
| 0 ... 600 | 100 ... 500 | 5 |
| Scale range in °F | Measuring range 1) in °F | Scale spacing in °F |
|---|---|---|
| -100 ... +150 | -70 ...+120 | 5 |
| -80 ... +120 | -40 ...+100 | 2 |
| -80 ... +240 | -50 ...+210 | 5 |
| -40 ... +120 | -20 ...+100 | 2 |
| 0 ... 140 | 20 ... 120 | 2 |
| 0 ... 200 | 20 ... 180 | 2 |
| 0 ... 250 | 30 ... 220 | 5 |
| 30 ... 300 | 60 ... 270 | 2 |
| 30 ... 400 | 80 ... 350 | 5 |
| 50 ... 400 | 100 ... 350 | 5 |
| 100 ... 800 | 200 ... 700 | 10 |
| 150 ... 750 | 200 ... 700 | 5 |
| 200 ... 1,000 | 300 ... 900 | 10 |
| Unit | ■ °C ■ °F ■ °C/°F (dual scale) ■ °F/°C (dual scale) | |
|---|---|---|
| Overtemperature stability 1) | ||
| End of scale range ≥ 50 °C [120 °F] ...≤ 120 °C [250 °F] | + 100 %overload safety referred to end of scale range | |
| End of scale range > 120 °C [250 °F] ...≤ 200 °C [400 °F] | + 50 %overload safety referred to end of scale range | |
| End of scale range > 280 °C [536 °F] ...≤ 400 °C [752 °F] | Max. 430 °C [800 °F] of end of scale range | |
| End of scale range > 400 °C [752 °F] ...≤ 600 °C [1112 °F] | Max. full scale range | |
| Dial | ||
| Scale graduation | ■ Single scale ■ Dual scale | |
| Scale colour | Single scale | Black |
| Dual scale | Red | |
| → Others on request | ||
| Material | Aluminium | |
| Pointer | ||
| Version | Adjustable pointer | |
| Pointer colour | Black | |
| Material | Aluminium |
View all (18)
| ModelTW10 | →see data sheetTW95.10 →see data sheetTW95.11 →see data sheetTW95.12 | |
|---|---|---|
| ModelTW15 | →see data sheetTW95.15 | |
| ModelTW25 | →see data sheetTW95.25 | |
| ModelTW45 | →see data sheetTW95.45 | |
| ModelTW50 | →see data sheetTW95.50 | |
| ModelTW55 | →see data sheetTW95.55 | |
| → Special thermowells on request |
| Ambient temperature range (at the case) | Unfilled | Filled |
|---|---|---|
| Instrument glass | -40 ...+100 °C 1) [-40 ...+212 °F] | ■ -40 ...+70 °C [-40 ...+160 °F] ■ -50 ...+70 °C [-60 ...+160 °F] |
| Laminated and polycarbonate window | -40 ...+70 °C 1) [-40 ...+160 °F] | ■ -40 ...+70 °C [-40 ...+160 °F] ■ -50 ...+70 °C [-60 ...+160 °F] |
| Storage temperature range | ||
| Without liquid dampening | -50 ...+70 °C [-60 ...+160 °F] | |
| With liquid dampening | -40 ...+70 °C [-40 ...+160 °F] | |
| Max. operating pressure at stem | Max. 25 bar, static | |
| Ingress protection (IP code) per IEC/EN 60529 | ■ IP65 ■ IP66 ■ IP67 ■ IP68 (continuous immersion to 5 m[16.4 | ft]) |
| Insertion length L 1 | 63 ... 1,000 mm[2.5 ... 39 in] | |
| Minimum/maximum length is dependent on the measuring range and diameter →See table on page 7 |
| Scale range in °C | Connection location | Back mount, adjustable stem and dial | ||||
|---|---|---|---|---|---|---|
| Ø 6 | Ø 8 | Ø 6 | Ø 8 | Ø 6 | Ø 8 | |
| -70 ... +70 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| -70 ... +30 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -60 ... +50 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -50 ... +50 | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -50 ... +100 | 80 [3.15] | 63 [2.48] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -50 ... +200 | 80 [3.15] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -50 ... +300 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| -50 ... +400 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| -50 ... +500 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| -40 ... +40 | 100 [3.94] | 90 [3.54] | 125 [4.92] | 100 [3.94] | 125 [4.92] | 100 [3.94] |
| -40 ... +60 | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -40 ... +80 | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -40 ... +160 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 63 [2.48] | 80 [3.15] | 63 [2.48] |
| -30 ... +30 | 125 [4.92] | 100 [3.94] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| -30 ... +50 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -30 ... +70 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -20 ... +40 | 125 [4.92] | 90 [3.54] | 125 [4.92] | 100 [3.94] | 125 [4.92] | 100 [3.94] |
| -20 ... +60 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -20 ... +80 | 80 [3.15] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -20 ... +100 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| -20 ... +120 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| -20 ... +140 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| -10 ... +50 | 125 [4.92] | 90 [3.54] | 125 [4.92] | 100 [3.94] | 125 [4.92] | 100 [3.94] |
| 0 ... 60 | 125 [4.92] | 90 [3.54] | 125 [4.92] | 100 [3.94] | 125 [4.92] | 100 [3.94] |
| 0 ... 80 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| 0 ... 100 | 80 [3.15] | 63 [2.48] | 100 [3.94] | 80 [3.15] | 100 [3.94] | 80 [3.15] |
| 0 ... 120 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| 0 ... 160 | 63 [2.48] | 63 [2.48] | 80 [3.15] | 63 [2.48] | 80 [3.15] | 63 [2.48] |
| 0 ... 200 | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] |
| 0 ... 250 | 80 [3.15] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| 0 ... 300 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 0 ... 400 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 0 ... 500 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 0 ... 600 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| Scale range in °F | Connection location | |||||
|---|---|---|---|---|---|---|
| Back mount | Lower mount | Back mount, adjustable stem and dial | ||||
| Ø 6 | Ø 8 | Ø 6 | Ø 8 | Ø 6 | Ø 8 | |
| -100 ... +150 | 90 [3.54] | 80 [3.15] | 90 [3.54] | 90 [3.54] | 90 [3.54] | 90 [3.54] |
| -80 ... +120 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| -80 ... +240 | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] | 90 [3.54] | 80 [3.15] |
| -40 ... +120 | 100 [3.94] | 90 [3.54] | 125 [4.92] | 100 [3.94] | 125 [4.92] | 100 [3.94] |
| 0 ... 140 | 90 [3.54] | 80 [3.15] | 100 [3.94] | 90 [3.54] | 100 [3.94] | 90 [3.54] |
| 0 ... 200 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 0 ... 250 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| 30 ... 300 | 80 [3.15] | 63 [2.48] | 80 [3.15] | 80 [3.15] | 80 [3.15] | 80 [3.15] |
| 30 ... 400 | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] |
| 50 ... 400 | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] | 63 [2.48] |
| 100 ... 800 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 150 ... 750 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] |
| 200 ... 1,000 | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4.92] | 125 [4,92] |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ATEX directive Hazardous areas - Ex h Zone 1 gas II 2G Ex h IIC T6 ...T1 Gb X Zone 21 dust II 2D Ex h IIIC T85 ...T450 °C Db | European Union | |
| KazInMetr Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS Permission for commissioning | Kazakhstan |
| Uzstandard Metrology, measurement technology | Uzbekistan | |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) DNV GL | Canada |
| Type approval for the shipbuilding industry - Nominal size: 63 mm[2.5"], 80 mm[3"], 100 mm[4"] - Dampening:With liquid dampening - Maximum insertion length: 500 mm[19.69 in] Location classification: Humidity DNVGL-CG-0339, section 3, class B Salt fog DNVGL-CG-0339, section 3, class D Vibration DNVGL-CG-0339, section 3, class B Use of a thermowell/protection tube is mandatory. | International |
| Certificates | ■ 2.2 test report ■ 3.1 inspection certificate with 3 test points (optionally with 5 test points) |
|---|
| SW Nominal size | G 1 Process con- nection | Ø d d Bauform 3 Dimensions in mm[ in ] Bauform Design | |||
|---|---|---|---|---|---|
| NS in mm["] | G | i | SW | d 4 | 3073050.06 Design 3 Ø d |
| 63, 80, 100, 160 [2,5, 3, 4, 6] SW | i i l G½B | 1 l 2 14 [0.55] G Ø d 4 | 27 [1.06] Ø d | 26 [1.02] | ■ 6 [0.24] ■ 8 [0.32] Bauform 1 |
| SW | G ½NPT i | l 2 19 [0.75] l 2 | Ø d 22 [0.87] | - | 3073050.06 Bauform 4 ■ 6 [0.24] ■ 8 [0.32] Design 1 3073050.06 |
| Nominal size | L Process connection l | Dimensions in mm[ in ] | ||
|---|---|---|---|---|
| NS in mm["] SW | G ca.40 i | i 1 | SW d 4 | Ø d |
| 63, 80, 100, 160 [2,5, 3, 4, 6] | G½B | 20 [0.79] | 27 [1.06] Ø d Ø G | ■ 6 [0.24] ■ 8 [0.32] Bauform 3073050.06 |
| M18 x 1.5 L | 17 [0.67] l 2 | 22 [0.87] | ■ 6 [0.24] ■ 8 [0.32] Design 4.1 |
| Nominal size | Dimensions in mm[ in ] G Ø Ø d | |||
|---|---|---|---|---|
| NS in mm["] | SW d 1 | G l Ød | a for axial | Ø d 3073050.06 a for adjustable stem and dial 3073050.06 |
| 63, 80, 100, 160 [2,5, 3, 4, 6] | 18 [0.82] | 8 [0.32] l 1 | 28 [1.1] l 2 SW | 30 [1.18] l 1 |
| Nominal size | Process connection | Dimensions in mm[ in ] | ||
|---|---|---|---|---|
| NS in mm["] | G L | i l 2 | SW | Ø d |
| 63, 80, 100, 160 [2,5, 3, 4, 6] SW 25 | G½B i | 8.5 [0.34] | 27 [1.06] d 4 | ■ 6 [0.24] ■ 8 [0.32] |
| Ø22 | M24 x 1.5 | 13.5 [0.53] | 32 [1.26] Ø d Ø G | ■ 6 [0.24] ■ 8 [0.32] 3073050.06 |
| Nominal size | Process con- nection | l 2 Dimensions in mm["] | |||
|---|---|---|---|---|---|
| NS in mm["] | ca.40 G | l 1 i | SW | d 4 | Ø d |
| 63, 80, 100, 160 [2,5, 3, 4, 6] | G½B | L 14 [0.55] | 27 [1.06] | 26 [1.02] | ■ 6 [0.24] ■ 8 [0.32] |
| ½NPT | 19 [0.75] | 22 [0.87} | - | ■ 6 [0.24] ■ 8 [0.32] |
| Nominal size | Process con- nection | Dimensions in mm["] | |||
|---|---|---|---|---|---|
| NS in mm["] | G | i | SW | d 4 | Ø d |
| 63, 80, 100, 160 [2,5, 3, 4, 6] | G½B | 14 [0.55] | 27 [1.06] | 26 [1.02] | ■ 6 [0.24] ■ 8 [0.32] |
| ½NPT | 19 [0.75] | 22 [0.87} | - | ■ 6 [0.24] ■ 8 [0.32] |
| Nominal size | Dimensions in mm[ in ] | |||||||
|---|---|---|---|---|---|---|---|---|
| NS in mm["] | Ø D | Ø d | b | b 1 1) | b 2 | F | ||
| G thread | NPT thread | G thread | NPT thread | |||||
| 63 [2,5] | 70 [2.76] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 45 [1.77] | 38 [1.5] | 39 [1.54] | 81 [3.19] | 77 [3.03] |
| 80 [3] | 83 [3.27] | ■ 6 [0.24] ■ 8 [0.32] | 23 [0.91] | 44 [1.73] | 37 [1.46] | 38 [1.5] | 88 [3.47] | 84 [3.31] |
| 100 [4] | 107 [4.21] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 45 [1.77] | 38 [1.5] | 39 [1.54] | 100 [3.94] | 95 [3.74] |
| 160 [6] | 167 [6.58] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 45 [1.77] | 38 [1.5] | 39 [1.54] | 130 [5.12] | 125 [4.92] |
| Nominal size | Dimensions in mm[ in] | ||||
|---|---|---|---|---|---|
| NS in mm["] | Ø D | Ø d | b | b 3 | F |
| 63 [2,5] | 70 [2.76] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 65 [2.56] | 67 [2.64] |
| 80 [3] | 83 [3.27] | ■ 6 [0.24] ■ 8 [0.32] | 23 [0.91] | 64 [2.52] | 67 [2.64] |
| 100 [4] | 107 [4.21] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 65 [2.56] | 67 [2.64] |
| 160 [6] | 167 [6.58] | ■ 6 [0.24] ■ 8 [0.32] | 24 [0.95] | 65 [2.56] | 67 [2.64] |
Couldn't find the answer in the documentation? An engineer will reply within a business day.