AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
T16.H 1
T16.H
In stock at WIKA
WIKA · Temperature measurement · Family T16

Digital temperature transmitter

For thermocouples, head- and rail-mounted version
Range
-270…2500 °C
Output
4-20mA
Accuracy
±0.045 % of ML (output)
Protection
IP00
CERoHS2.2 test report per EN 10204II 1G Ex ia IIC T6...T4 GaII 3G Ex ic IIC T6...T4 Gc XII 1D Ex ia IIIC T135 °C DaEx ec IIC T6...T4 Gc XEx ia IIC/IIB/IIAEx ia IIICEx ic IIC/IIB/IIAEx ecEx ec IIC/IIB/IIAZone 1 gas 1 Ex ib IIC T4/T5/T6Zone 2 gas 2 Ex ic IIC T4/T5/T6Zone 20 dust DIP A20 Ta 135 °CZone 21 dust DIP A21 Ta 135 °C
Price
From €167
Confirm at order time
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These temperature transmitters are designed for universal use in plant and machine building, and also in the process industry. They offer high accuracy and excellent protection against electromagnetic influences (EMI). Via the WIKAsoft-TT configuration software and the model PU-548 programming unit, the model T16 temperature transmitters can be parameterised very easily, quickly and with a clear overview.

Besides the selection of the sensor type and the measuring range, the software enables the error signalling operation, damping, several measuring location descriptions and process adjustment to be stored. Furthermore, the WIKAsoftTT software offers a line recording functionality where the temperature profile for the thermocouple connected to the T16 can be displayed.

For approvals, see page 8

Fig. left: head-mounted version, model T16.H Fig. right: rail-mounted version, model T16.R

The model T16 transmitter features diverse monitoring functions, such as sensor break monitoring and measuring range monitoring. Moreover, these transmitters have comprehensive cyclic self-monitoring functionality.

Special features

  • For the connection of all standard thermocouples
  • High accuracy
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • EMC stability in compliance with the latest standard (EN 61326-2-3:2013)
Configurator · Step by step

Build a T16 for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 3
Configuration structure· click a highlighted segment to jump to that parameter
Your configuration
  • DesignHead
  • Explosion protectionWithout
  • Ignition protection typeWithout
  • Explosion protection 1.Additional approvalsWithout
  • Explosion protection 2.Additional approvalsWithout
  • Permissible ambient temperature transmitterStandard -40...85°C
  • Configuration—
  • Configuration sensorThermocouple Type K
  • Input configurationThermocouple (CJC internal)
  • Unit°C
  • Measuring range start value - signPlus (incl. 0)
  • Measuring range start value0
  • Measuring range end value - signPlus (incl. 0)
  • Measuring range end value—
  • Transmitter Signalling of error—
  • Configuration protocolWithout
  • FastenersWithout
  • CertificatesWithout
AI suggestion by parameters

Finish your configuration

Select every option to submit the request.

Send request
Send request