AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
OLS-2 1
OLS-2
On order
WIKA · Level measurement · Family OLS

Optoelectronic level switch and switching amplifier

Optoelectronic level switch for limit level detection in liquids, suitable for cryogenic and industrial applications with temperature ranges from -269 to +400 °C and pressure up to 500 bar.
Range
0.025…0.96 m
Output
SPDT relay
Accuracy
±0.5 mm
Protection
IP66/IP68
UKCACEEMCATEXIECExRoHSREACHEx ib IIC T6...T1 Ga/GbEx ib IIIC T85...T400 °C DbEx ib IIC T6 ...T1 Ga/GbEx ib IIIC T85 ...T400 °C DbII 1/2G Ex ib IIC T6 ...T1 Ga/Gb
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model OLS-2 optoelectronic level switch is used for the detection of limit levels in liquids. The OLS-2 operates widely independent of physical characteristics such as refractive index, colour, density, dielectric constant and conductivity. Measurement of level change is also done in small volumes.

The model OLS-2 limit level switch consists of an infrared LED and a phototransistor. The light of the LED is directed into a prism. So long as the sensor tip of the prism is in the gaseous phase, the light is reflected within the prism to the receiver. When the liquid in the vessel rises and wets approximately 2/3 of the glass tip, the infrared light beam into the liquid is interrupted and only a small portion reaches the receptor.

for further approvals, see page 3

Fig. left: Model OLS-2, optoelectronic level switch Fig. right: Model OSA-SC, switching amplifier with Bluetooth ® function

This difference is evaluated by the electronics and triggers a switching operation.

The instruments are very robust and designed for rough operating conditions. The installation position can be as required. Thus, the OLS-2 can be installed from above, from below, vertically, horizontally or at an angle.

The cable to the model OSA-SC switching amplifier does not need any shield, enabling easy and economic cabling. The change in the alarm direction, the sensitivity of the switching threshold, as well as a time delay of up to 8 seconds can be easily transferred to the OSA-SC via Bluetooth ® app and changed individually.

Special features

  • Temperature ranges from -269 ... +400 °C [-452 ... +752 °F]
  • Versions for pressure ranges from vacuum to 500 bar [7,252 psi]
  • Special versions: High pressure, interface measurement
  • Explosion-protected versions
  • Signal processing is made using a separate model OSA-SC switching amplifier
Identification
ModelOLS-2
Product familyOLS
SubcategoryOptoelectronic level switch
Measuring range
Level ranges0.025…0.025 m · 0.035…0.96 m · 0.025…0.96 m
Process conditions
Process connection
G 1/2 male1/2 NPT maleASME B16.5 1/2" ... 2"DIN EN 1092-1 DN20 ... DN50G1/2, Außengewinde1/2 NPT, Außengewinde1/2" ... 2" per ASME B16.5DN20 ... DN50 per DIN EN 1092-1G1/2 external thread1/2 NPT external threadASME B16.5 flange 1/2*...2*DIN EN 1092-1 flange DN20...DN50
Process temperature−269…+400 °C
Max process pressure500 bar
Measurement technologyvibration_fork
Electrical characteristics
Output signalSPDT relay
Power supplyDC 12 ... 30 V
Electrical connection4-pin SMD PCB terminal
Materials
Wetted parts materialStainless steel 1.4571, Hastelloy, Clad core glass, Fused quartz, Sapphire glass
Operating environment
Ambient temperature−55…+80 °C
IP ratingIP66/IP68
Certifications and approvals
Certifications
UKCACEEMCATEXIECExRoHSREACH
Explosion protection
Ex ib IIC T6...T1 Ga/GbEx ib IIIC T85...T400 °C DbII 1/2G Ex ib IIC T6 ...T1 Ga/Gb II 2D Ex ib IIIC T85 ...T400 °C DbII 1/2G Ex ib IIC T6 ...T1 Ga/GbII 2D Ex ib IIIC T85 ...T400 °C DbIECEx
Additional details
Datasheet languagesEN, DE
Tables from datasheet
Specifications
Measuring length (switch point) ML■ 25 mm[0.98 in] ■ With extension of the light guide 35 ... 960 mm[1.38 ... 37.80 in]
Insertion length IL29 mm[1.14 in] (ML + 4 mm[0.16 in])
Medium temperatureStandard version without cooling element-65 ...+170 °C [-85 ...+338 °F]
High-/Low-temperature version with cooling element-269 ...+400 °C [-452 ...+752 °F]
Ambient temperature-55 ...+80 °C [-67 ...+176 °F]
Storage temperature-20 ...+80 °C [-4 ...+176 °F]
Pressure range-1 ...+500 bar [-14.50 ... +7,252 psi] depending on p/T rating (pressure/temperature assignment)
Measurement type■ Level measurement with glass tipV shape ■ Interface layer with glass tip U shape
Process connection
Mounting thread■ G1/2, Außengewinde ■ 1/2 NPT, Außengewinde
Process connection flange■ 1/2" ... 2" per ASME B16.5 ■ DN20 ...DN50 per DIN EN 1092-1
Light guide■ Clad core glass (ML: max. 900 mm[35.43 in]) ■ Fused quartz (ML: max. 200 mm[7.87 in]) ■ Sapphire glass (ML: max. 60 mm[2.36 in])
Mounting positionAs required
Measurement accuracy±0.5 mm[± 0.02 in]
Repeat accuracy±0.1 mm[± 0.04 in]
Light sourceIR light 930 nm
Protection of the light guideMetal protective housing with lateral opening slots
Ambient lightMax. 100 Lux
Material
CaseStainless steel 1.4571
Light guide (wetted)■ Stainless steel 1.4571 ■ Hastelloy
Other materials on request
Cable glandM20 x 1.5
Terminal connection
Termination point4-pin SMDPCBterminal
Single-wire/fine-wired conductor0.5 ...1.5mm 2 / 20 ...16AWG
Fine-wired conductor with end splice with/without plastic collar0.5 ...0.75mm 2
Ingress protection per IEC/EN 60529■ IP66 ■ IP68
Specifications
Ambient temperature-20 ...+60 °C [-4 ...+140 °F]
Storage temperature-20 ...+60 °C [-4 ...+140 °F]
Auxiliary powerDC 12 ... 30 V, protected against reverse polarity
Power dissipation / Power consumption≤ 0.9W
OutputChange-over contact (SPDT)
Max. connection cross-section2.5mm 2
Max. cable length175 ... 600 m[574.1 ... 1,968.5 ft] (for 0.5 ...1.5mm 2 )
Ingress protection per IEC/EN 60529IP20
Dimensions29 x 130 x 127 mm[1.14 x 5.12 x 5 in] (W x H x D)
MountingOn 35-mm DIN rail per EN 60715:2015
General data
Functions■ Alarm direction selectable for high or low alarm ■ Pick-up delay and drop-out delay settable up to 8 seconds for signal relay
Monitoring■ Wire break signal circuit ■ Short-circuit signal circuit ■ Internal auxiliary power, fail-safe ■ Green status LED for auxiliary power monitoring ■ Yellow status LED for alarm monitoring (switched relay)
ModelArticle number
OSA-SC (standard version)14602554
OSA-SCI (Ex i version)14602553
View all (6)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
UKCA Electromagnetic compatibility regulationsUnited Kingdom
LogoDescriptionRegion
EU declaration of conformityEuropean Union
ATEX directive Hazardous areas
- Ex iZone 1 mounting to zone 0 gas Zone 21 dustII 1/2G Ex ib IIC T6 ...T1 Ga/Gb II 2D Ex ib IIIC T85 ...T400 °C Db
IECEx Hazardous areasInternational
- Ex iZone 1 mounting to zone 0 gas Zone 21 dustEx ib IIC T6 ...T1 Ga/Gb
Ex ib IIIC T85 ...T400 °C Db