Fault · SINAMICS G130, G150, S120, S150

F36216Hub: undervoltage fault 24 V supply

What it means

F36216 reports that the 24 V power supply on the DRIVE-CLiQ Hub Module has undershot the fault threshold. The drive takes no automatic action on this fault; depending on the drive's configuration, the same condition can also be issued as an alarm (A) or as a message with no reaction (N).

Why it appears

  • The 24 V supply of the DRIVE-CLiQ Hub Module dropped below the fault threshold.

What to check

  1. Check the supply voltage of the component involved.
  2. Replace the component involved.

Reading the message value

  • The drive stores the fault value in r0949; interpret the value as a decimal number.
  • The value is the Actual operating voltage in 0.1 °C resolution — the resolution is printed this way in the manual.

Parameters the manual names

  • r0949 — fault value; read it to see the actual operating voltage the Hub Module measured when the fault was raised (interpret the value as decimal).

Acknowledging and restarting

The fault is acknowledged immediately; a POWER ON also acknowledges it. Because the drive performs no automatic reaction, it simply waits until the supply problem has been corrected and the fault acknowledged. Where the same condition is configured as an alarm (A) or with no reaction (N), no separate acknowledgement is required.

The same on every family

Every manual that describes F36216 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONE (OFF1, OFF2)IMMEDIATELY (POWER ON)Supply voltage fault (undervoltage) (3)Terminal Board (TB)SINAMICS S120, S150 List Manual · p. 3250
G130, G150NONE (OFF1, OFF2)IMMEDIATELY (POWER ON)Supply voltage fault (undervoltage) (3)Terminal Board (TB)SINAMICS G130, G150 List Manual · p. 1912

The drives this code lives on

F36216 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F36216 mean on a SINAMICS G130, G150, S120 or S150?

It means the 24 V power supply on the DRIVE-CLiQ Hub Module has undershot the fault threshold. The fault value in r0949 shows the actual operating voltage at the moment of the fault.

How do I fix F36216?

Check the supply voltage of the component involved and replace the component involved. Afterwards the fault is acknowledged immediately, or by a POWER ON.

What does the fault value of F36216 contain?

r0949, interpreted as a decimal number, holds the actual operating voltage with a resolution of 0.1, exactly as the manual prints it.

Does F36216 shut the drive down?

No automatic reaction is assigned to this fault. Depending on the configuration, the same condition can also appear as an alarm (A) or with no reaction (N).