SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Fault · SINAMICS G130, G150, S120, S150

F35043TM54F: 24 V overvoltage

What it means

F35043 reports that an overvoltage condition was detected on the 24 V power supply for the Terminal Module 54F (TM54F). As fault response, failsafe input terminal signals are transferred to the motion monitoring functions.

Why it appears

  • An overvoltage condition was detected on the 24 V power supply for the Terminal Module 54F (TM54F).

What to check

  1. Check the 24 V DC power supply for the TM54F.
  2. Carry out the safe acknowledgment (p10006).

Parameters the manual names

  • p10006 — SI Motion acknowledgment internal event F-DI (processor 1): the safe acknowledgment of this fault is carried out with this parameter.

Acknowledging and restarting

Once the 24 V DC power supply for the TM54F has been checked and the overvoltage condition eliminated, the fault is cleared by carrying out the safe acknowledgment with p10006.

The same on every family

Every manual that describes F35043 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONEIMMEDIATELYSupply voltage fault (overvoltage) (3)Terminal Module (TM)SINAMICS S120, S150 List Manual · p. 3205
G130, G150NONEIMMEDIATELYSupply voltage fault (overvoltage) (3)Terminal Module (TM)SINAMICS G130, G150 List Manual · p. 1874

The drives this code lives on

F35043 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F35043 mean on a SINAMICS drive?

It reports that an overvoltage condition was detected on the 24 V power supply for the Terminal Module TM54F. As fault response, failsafe input terminal signals are transferred to the motion monitoring functions.

How do I clear fault F35043?

Check the 24 V DC power supply for the TM54F, then carry out the safe acknowledgment with p10006.

Which parameter performs the safe acknowledgment for F35043?

p10006 — SI Motion acknowledgment internal event F-DI (processor 1) — is the parameter with which the safe acknowledgment is carried out after the supply has been corrected.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F35xxx group · SINAMICS manuals · Siemens manuals