What it means
F32950 means that an internal software error has occurred in the Sensor Module Encoder 2, the drive's second encoder evaluation module. The error lies in the Sensor Module's own software; the only cause the manual names is this software error itself. The fault value stored with the message merely identifies the internal fault source and is, by the manual's own statement, meant only for internal Siemens troubleshooting.
Why it appears
- An internal software error has occurred in the Sensor Module Encoder 2. The manuals name no further cause for this fault.
What to check
- If necessary, upgrade the firmware in the Sensor Module to a later version.
- Contact Technical Support; the fault value information in r0949 is intended for their internal diagnosis.
Reading the message value
- The drive writes the fault value into r0949; interpret the value as a decimal number.
- The value contains information about the fault source.
- The manual publishes no decoding of individual values and states that this information is only for internal Siemens troubleshooting.
Parameters the manual names
- r0949 — fault value of the message. For F32950 it holds the information about the fault source, read as a decimal; there is no value to set or change here, the parameter only serves the internal diagnosis of this software error.
Acknowledging and restarting
Acknowledging this fault requires a POWER ON: the drive must be switched off and on again before F32950 is cleared and the drive can be restarted. If the fault returns after the power cycle, follow the remedy above — Sensor Module firmware upgrade, then Technical Support.
The same on every family
Every manual that describes F32950 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | OFF1 (OFF2) | POWER ON | Hardware/software error (1) | Sensor Module Encoder 2 | SINAMICS S120, S150 List Manual · p. 3132 |
| G130, G150 | OFF1 (OFF2) | POWER ON | Hardware/software error (1) | Sensor Module Encoder 2 | SINAMICS G130, G150 List Manual · p. 1807 |
The drives this code lives on
F32950 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does SINAMICS fault F32950 mean?
It reports an internal software error in the Sensor Module Encoder 2, the drive's second encoder evaluation module. The fault value in r0949 points to the internal fault source and is intended only for internal Siemens troubleshooting.
How do I clear fault F32950?
Only a POWER ON acknowledges it: switch the drive's power supply off and on again. The drive can then be restarted.
How do I fix fault F32950?
The manual's remedy is to upgrade the firmware in the Sensor Module to a later version if necessary and otherwise to contact Technical Support; there is no parameter to adjust on site.