Alarm · SINAMICS G130, G150, S120, S150

A33999Encoder 3: Unknown alarm

What it means

A33999 “Encoder 3: Unknown alarm” is raised when the Sensor Module that supplies encoder 3 reports an alarm which the firmware of the Control Unit cannot interpret. According to the manual this happens in particular when the firmware on the Sensor Module is more recent than the firmware on the Control Unit, so the component reports an alarm number the Control Unit does not yet know. The component concerned is Sensor Module Encoder 3. Depending on how the drive is configured, the same condition can also be issued as a fault (F) or as a message with no reaction (N).

Why it appears

  • An alarm has occurred on the Sensor Module for encoder 3 that the Control Unit firmware cannot interpret.
  • This can occur if the firmware on this component is more recent than the firmware on the Control Unit.

What to check

  1. Read the alarm number from r2124; the manual specifies that the value is interpreted in decimal. This tells you which alarm the Sensor Module has raised.
  2. Compare the firmware versions: r0148 shows the Sensor Module firmware version and r0018 the Control Unit firmware version, so you can see which component carries the older firmware.
  3. Replace the firmware on the Sensor Module by an older firmware version, or upgrade the firmware on the Control Unit.
  4. If you need to know what the new alarm means, the manual notes: If required, the significance of this new alarm can be read about in a more recent description of the Control Unit.

Reading the message value

  • The message value is shown as “New message: %1”.
  • Alarm value (r2124, interpret decimal): Alarm number — the number of the alarm that the Sensor Module raised and the Control Unit firmware cannot interpret.

Parameters the manual names

  • r2124 — alarm value: read it in decimal to find the number of the alarm the Sensor Module for encoder 3 has raised.
  • r0148 — Sensor Module firmware version: compare it with the Control Unit version to see whether the Sensor Module is the newer component; fitting an older Sensor Module firmware is the first remedy.
  • r0018 — Control Unit firmware version: upgrading it is the second remedy, so that the Control Unit can again interpret the alarms of the Sensor Module.

Acknowledging and restarting

While the condition stands as alarm A33999, the drive takes no automatic response, the operating state is not changed and no acknowledgment is required. If the drive is configured to issue the same condition as a fault instead, the fault is acknowledged immediately (POWER ON is the alternative acknowledgment setting). No further reset is described; removing the firmware mismatch between Sensor Module and Control Unit is what clears the message.

The same on every family

Every manual that describes A33999 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEActual position/speed value incorrect or not available (11)Sensor Module Encoder 3SINAMICS S120, S150 List Manual · p. 3182
G130, G150NONENONEActual position/speed value incorrect or not available (11)Sensor Module Encoder 3SINAMICS G130, G150 List Manual · p. 1852

The drives this code lives on

A33999 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A33999 Encoder 3 Unknown alarm mean?

The Sensor Module for encoder 3 has raised an alarm that the Control Unit firmware cannot interpret. The manual states this occurs when the firmware on the Sensor Module is more recent than the firmware on the Control Unit.

How can I see which alarm the Sensor Module raised?

Read r2124 and interpret the value in decimal; it holds the alarm number behind the “New message” indication.

How do I clear A33999?

Either replace the Sensor Module firmware with an older version (the version is shown in r0148) or upgrade the Control Unit firmware (version in r0018). The significance of the new alarm can be read in a more recent description of the Control Unit.

Does A33999 stop the drive?

No. As an alarm the drive takes no automatic response and no acknowledgment is required; only if it is issued as a fault must it be acknowledged immediately (POWER ON being the alternative).