Alarm · SINAMICS G130, G150, S120, S150

A07474EPOS: End of traversing range reached

What it means

A07474 is the EPOS message «End of traversing range reached»: while traversing, the axis has arrived at the limit of its traversing range. As an alarm the drive takes no automatic action — it only reports the position, and no acknowledgment is needed. Depending on the drive's configuration, the same condition can also be issued as a fault; in that case the drive switches off with OFF1 (OFF2 or OFF3 can apply instead) and the fault must be acknowledged immediately before a restart.

Why it appears

  • While traversing, the axis has reached the limit of its traversing range.

What to check

  1. Move the axis away from the limit by traversing in the negative direction.
  2. If the drive raised the condition as a fault rather than an alarm, acknowledge it immediately and then restart the drive.

Acknowledging and restarting

The alarm itself needs no acknowledgment. If the condition is output as a fault, the drive reacts with OFF1 (OFF2, OFF3) and must be acknowledged immediately; it can then be restarted.

The same on every family

Every manual that describes A07474 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2825
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1562

The drives this code lives on

A07474 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A07474 mean?

It is the EPOS message «End of traversing range reached»: during traversing, the axis has moved to the limit of its traversing range.

How do I clear A07474?

Move the axis away in the negative direction. The alarm itself requires no acknowledgment; if the drive has raised the condition as a fault, acknowledge it immediately.

Does A07474 stop the drive?

As an alarm, no — the drive takes no automatic reaction. If the condition is issued as a fault, the drive reacts with OFF1 (OFF2, OFF3) and must be acknowledged immediately.