Alarm · SINAMICS G130, G150, S120, S150

A07473EPOS: Beginning of traversing range reached

What it means

A07473 is the EPOS message Beginning of traversing range reached: while traversing, the axis has moved to the limit of its traversing range. The manuals describe this message identically for G130, G150, S120 and S150. As an alarm it triggers no automatic drive reaction; depending on how the drive is configured, the same condition can also be issued as the fault F07473 instead, in which case the drive performs OFF1 (OFF2, OFF3).

Why it appears

  • While traversing, the axis has moved to the limit of the traversing range — the beginning of the range has been reached.

What to check

  1. Move the axis away in the positive direction.
  2. If the condition was raised as the fault F07473 rather than as this alarm, acknowledge it as described under Reset and restart the drive.

Acknowledging and restarting

As an alarm, A07473 does not have to be acknowledged — the drive takes no automatic action on it. The same condition can also be configured as a fault (F07473); in that case the drive performs OFF1 (OFF2, OFF3) and the message is acknowledged IMMEDIATELY. In both cases the remedy is the same: move the axis away in the positive direction.

The same on every family

Every manual that describes A07473 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONENONEApplication/technological function faulted (17)NoneSINAMICS G130, G150 List Manual · p. 1561
S120, S150NONENONEApplication/technological function faulted (17)NoneSINAMICS S120, S150 List Manual · p. 2825

The drives this code lives on

A07473 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A07473 mean?

It is the EPOS alarm 'Beginning of traversing range reached': while traversing, the axis has moved to the limit of its traversing range.

Does A07473 stop the drive?

No. As an alarm it triggers no automatic reaction and needs no acknowledgement. Only the fault variant F07473 stops the drive (OFF1, OFF2 or OFF3).

How do I clear A07473?

Move the axis away in the positive direction. As an alarm, no acknowledgement is required; the fault variant F07473 is acknowledged IMMEDIATELY.

Which drives report A07473?

G130, G150, S120 and S150 — the manuals describe the message identically for all of them.