What it means
A01331 is a topology alarm. The drive raises it when at least one component in the configuration is not assigned to a drive object — for example because the component could not be assigned automatically during commissioning, or because the parameters for the data sets are not set correctly. The G130/G150 and S120/S150 manuals describe the message identically, so one description covers all four families.
Why it appears
- At least one component in the topology has no assignment to a drive object.
- During commissioning, a component could not be automatically assigned to a drive object.
- The parameters for the data sets are not correctly set.
What to check
- Identify the affected component: the alarm value in r2124, interpreted as a decimal number, gives the component number of the unassigned component.
- Assign this component to a drive object.
- Check the parameters for the data sets. The manual gives these examples: power unit (p0121); motor (p0131, p0186); encoder interface (p0140, p0141, p0187 ... p0189); encoder (p0140, p0142, p0187 ... p0189); Terminal Module (p0151); option board (p0161).
Reading the message value
- The message value of the alarm carries the component number (placeholder %1).
- The alarm value is stored in r2124 and is to be interpreted decimal; it likewise contains the component number of the unassigned component. No bit decoding is given for this alarm.
Parameters the manual names
- r2124 — alarm value: read it as a decimal number to obtain the component number of the unassigned component.
- p0121 — power unit component number: check or set it when the power unit is the unassigned component.
- p0131 — motor component number: belongs to the motor assignment verified for this alarm.
- p0186 — Motor Data Sets (MDS) number: verified together with the motor component number.
- p0140 — number of Encoder Data Sets (EDS): named in both the encoder interface and the encoder examples.
- p0141 — encoder interface (Sensor Module) component number: checked when the encoder interface is the component without assignment.
- p0187 ... p0189 — encoder data set numbers (encoder 1 ... encoder 3): appear in the encoder interface and encoder examples of the remedy.
- p0142 — encoder component number: checked when the encoder itself is the unassigned component.
- p0151 — Voltage Sensing Module component number; the remedy lists it under the Terminal Module example.
- p0161 — option board component number: checked when the option board is the unassigned component.
Acknowledging and restarting
The drive takes no automatic reaction to this alarm and no acknowledgement is required. Once the component has been assigned to a drive object and the data-set parameters are set correctly, the alarm condition is removed.
The same on every family
Every manual that describes A01331 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| G130, G150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS G130, G150 List Manual · p. 1404 |
| S120, S150 | NONE | NONE | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS S120, S150 List Manual · p. 2593 |
The drives this code lives on
A01331 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does alarm A01331 mean on a SINAMICS drive?
It means the topology contains at least one component that is not assigned to a drive object — typically because automatic assignment during commissioning failed or because the data-set parameters are not set correctly.
How do I find out which component A01331 refers to?
Read r2124 and interpret it as a decimal number: it contains the component number of the unassigned component, which is also carried in the alarm's message value.
Does A01331 have to be acknowledged?
No acknowledgement is required. The alarm condition is gone once the component is assigned to a drive object and the data-set parameters have been checked.
Which parameters are checked for A01331?
Depending on the component: p0121 (power unit), p0131 and p0186 (motor), p0140, p0141, p0187 ... p0189 (encoder interface), p0140, p0142, p0187 ... p0189 (encoder), p0151 (Terminal Module) and p0161 (option board).
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the A01xxx group · SINAMICS manuals · Siemens manuals