Alarm · SINAMICS G130, G150, S120, S150

A01314Topology: Component must not be present

What it means

A01314 (“Topology: Component must not be present”) is raised when a component has been configured with the setting “deactivate and not present”, but the drive still finds this component in the topology. In other words, the configured picture of the drive and the components that are actually present do not agree.

Why it appears

  • A component has been set to “deactivate and not present”, but this component is still in the topology.

What to check

  1. Read the alarm value in r2124 (see below) to identify the component concerned: the component number, its component class and the connection number. The component class and the connection number are described in F01375.
  2. Either remove the corresponding component, or change the setting “deactivate and not present” for this component so that the configuration matches the actual topology again. The relevant activate/deactivate parameter depends on the component and is listed below.
  3. Under “Topology --> Topology view”, the commissioning tool where relevant offers improved diagnostics capability, for example a setpoint/actual value comparison.

Reading the message value

  • The alarm value is stored in r2124 and must be interpreted hexadecimal; its layout is ddccbbaa hex:
  • aa = component number
  • bb = component class of the component
  • cc = connection number

Parameters the manual names

  • r2124 (Alarm value) — read the alarm value here, interpreted hexadecimal, to obtain the component number, the component class and the connection number of the component that must not be present.
  • p0105 (Activate/deactivate drive object, DO act/deact) — here the “deactivate and not present” setting is made for a drive object.
  • p0125 (Activate/deactivate power unit components, PU_comp act/deact) — the same setting for power unit components.
  • p0145 (Activate/deactivate encoder interface, Enc_intf act/deact) — the same setting for the encoder interface.
  • p0155 (Voltage Sensing Module activate/deactivate, VSM act/deact) — the same setting for the VSM.
  • p0165 (Activate/deactivate filter module, FM act/deact) — the same setting for the FM; this parameter is additionally cross-referenced for S120/S150.

Acknowledging and restarting

The alarm needs no acknowledgement, and the drive takes no automatic action in response to it. Once you have removed the component or changed its “deactivate and not present” setting so that the topology matches the configuration again, the message clears without any further step.

What differs between the drive families

Straight from the manuals' own fields — A01314 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1399
S120, S150Error in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2588

The drives this code lives on

A01314 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A01314 mean?

A component has been configured as “deactivate and not present”, but the drive still detects this component in the topology. The configuration and the components actually present do not match.

How do I find out which component triggers A01314?

Read the alarm value in r2124 as a hexadecimal value: aa gives the component number, bb the component class of the component and cc the connection number. Component class and connection number are described in F01375.

How do I clear alarm A01314?

Remove the corresponding component, or change its “deactivate and not present” setting (p0105, p0125, p0145, p0155, p0165, depending on the component). No acknowledgement is needed.

Does A01314 shut the drive down?

No. The drive takes no automatic action in response to this alarm; it only reports that the configuration and the actual topology do not agree.