Measuring insert
Description
The measuring inserts for resistance thermometers described here are designed for installation in a thermometer model TR10-L. Operation without thermowell is appropriate only in special cases. The measuring insert is made of flexible, mineral-insulated sheathed cable. The sensor is located in the tip of the measuring insert. The measuring inserts are delivered with pressure springs to ensure that the measuring inserts are pressed down to the thermowell bottom.
The following versions are possible:
- ■ With mounted sleeve to suit inner diameter of the thermowell - ■ Without terminal block - ■ With transmitter
Type and number of sensors, accuracy and connection method can each be selected to suit the respective application.
for further approvals see page 2
Special features
- Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
- Made of mineral-insulated sheathed measuring cable
- For all standard thermowell designs
- Spring-loaded design
- Explosion-protected versions are available for many approval types (see data sheet page 2)
| Model | TR10-K |
| Product family | TR10 |
| Subcategory | Measuring insert |
| Temperature ranges | −196…+600 °C · −100…+450 °C · −50…+250 °C · −50…+500 °C · −30…+300 °C · +0…+150 °C |
| Safety integrity level (SIL) | SIL 2 |
| Process temperature | −196…+600 °C |
| Output signal | 4-20mA · HART |
| Electrical connection | 2-wire, 3-wire, 4-wire |
| Probe material | stainless steel |
| Certifications | RoHSGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardATEXIECExEACEx UkraineINMETROCCCKCs-KOSHAPESOEMC directive EN 61326REACHCEEMC directive |
| Explosion protection | II 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Gb0Ex ia IIC T6 ... T1 Ga XEx ia IIC T3 ... T6 GaEx ia IIC T3 ... T6 GbEx ia IIC T1 ~ T6 GaEx e IIC T1 ~ T6 GbEx nA IIC T1 ~ T6 GcEx ia IIC T4…T6Ex ib IIC T4 ... T6IECEx (in conjunction with ATEX)EAC Ex i Zone 0 gas 0Ex ia IIC T6...T1 Ga XEx Ukraine Ex i Zone 0 gas II 1G Ex ia IIC T1...T6 GaINMETRO Ex i Zone 0 gas Ex ia IIC T3...T6 GaCCC Hazardous areas Ex i Zone 0 gas Ex ia IIC T1~T6 GaKCs - KOSHA PESOGOST Zone 1 gas Ex ia IICT1…T6 GbKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEx i Zone 0 gas II 1G Ex ia IIC T1 ...T6 GaZone 1 gas II 2G Ex ia IIC T1 ...T6 Gb | European UnionIECEx (option)-in conjunction with ATEXEx i Zone 0 gas Ex ia IIC T1 ...T6 Ga | InternationalEAC (option)Ex i Zone 0 gas 0Ex ia IIC T6 ...T1 Ga X | Eurasian Economic CommunityEx i Zone 0 gas II 1G Ex ia IIC T1 ...T6 Ga | UkraineINMETRO (option)Ex i Zone 0 gas Ex ia IIC T3 ...T6 GaEx e Zone 1 Gas Ex e IIC T1 ~T6 GbEx n Zone 2 Gas Ex nA IIC T1 ~T6 Gc | ChinaEx i Zone 0 gas Ex ia IIC T4...T6Zone 1 gas Ex ib IIC T4...T6 | South KoreaPESO (option)Ex i Zone 0 gas Ex ia IIC T1...T6 GaZone 1 gas Ex ia IIC T1...T6 Gb | India |
| Sensor type | Pt100 |
| Sensor class | A, B, AA |
| Probe length | 1100 mm |
| Probe diameter | 3 mm |
| Thermowell | No |
| Datasheet languages | EN, DE |
| Logo | Description | Country | ||
|---|---|---|---|---|
| EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application) | European Union | |||
| International | ||||
| IECEx (option) - in conjunction with ATEX | ||||
| EAC (option) Hazardous areas - Ex i Zone 0 gas 0Ex ia IIC T6 ...T1 Ga X | Eurasian Economic Community | |||
| Ex Ukraine (option) Hazardous areas Ex i Zone 0 gas II 1G Ex ia IIC T1 ...T6 Ga | Ukraine | |||
| INMETRO (option) | ||||
| Hazardous areas - Ex i Zone 0 gas Ex ia IIC T3 ...T6 Ga Zone 1 gas Ex ia IIC T3 ...T6 Gb (option) 2) | ||||
| CCC Hazardous areas - | China | |||
| Ex i Zone 0 gas Ex ia IIC T1 ~ T6 Ga | South Korea | |||
| KCs - KOSHA (option) PESO | India | |||
| - | Hazardous areas | |||
| - Ex i Zone 0 gas Hazardous - Ex i | Zone 1 gas (option) areas Zone 0 gas | Ex ia IICT4…T6 Ex ib IIC T4 ...T6 Ex ia IICT1…T6 Ga | ||
| GOST (option) | Russia | |||
| Zone 1 gas Ex ia IICT1…T6 Gb Metrology, measurement technology | ||||
| KazInMetr (option) | Kazakhstan | |||
| Metrology, measurement technology |
| Logo | Description | Country |
|---|---|---|
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| BelGIM (option) Metrology, measurement technology | Belarus | |
| UkrSEPRO (option) Metrology, measurement technology | Ukraine | |
| Uzstandard (option) Metrology, measurement technology | Uzbekistan |
| Single elements | 1 x 2-wire 1 x 3-wire 1 x 4-wire |
|---|---|
| Dual elements | 2 x 2-wire 2 x 3-wire 2 x 4-wire 2) |
| Class | Sensor construction | |
|---|---|---|
| Wire-wound | Thin-film | |
| Class B | -196 ...+600 °C | -50 ...+500 °C |
| Class A 3) | -100 ...+450 °C | -30 ...+300 °C |
| Class AA 3) | -50 ...+250 °C | 0 ... 150 °C |
View all (8)
| Output signal 4 ... 20 mA, HART ® protocol | Model T32 | Model T91.10 | |
|---|---|---|---|
| Data sheet | TE 15.01 | TE 32.04 | TE 91.01 |
| Output | |||
| 4 ...20mA | x | x | x |
| HART ® protocol | - | x | - |
| Connection method | |||
| 1 x 2-wire, 3-wire or 4-wire | x | x | x |
| Measuring current | < 0.2mA | < 0.3mA | 0.8 ...1mA |
| Explosion protection | Optional | Optional | - |
| Measuring insert length l 5 inmm | Tolerance inmm |
|---|---|
| 75 ... 825 | +2 0 |
| > 825 | +3 0 |
| Measuring insert diameter Ø d inmm | Index per DIN 43735 | Tolerance inmm | |
|---|---|---|---|
| 3 1) | Standard | 30 | 3 ±0.05 |
| 6 | Standard | 60 | 6 0 -0,1 |
| 8 (6 mmwith sleeve) | Standard | - | 8 0 -0,1 |
| 8 | Standard | 80 | 8 0 -0,1 |
| 1/8 in [3.17 mm] 1) 1/4 in [6.35 mm] 3/8 in [9.53 mm] | On request | - | - |
| Certification type | Measurement accuracy | Material certificate |
|---|---|---|
| 2.2 test report | x | x |
| 3.1 inspection certificate | x | x |
| DKD/DAkkS calibration certificate | x | - |
Couldn't find the answer in the documentation? An engineer will reply within a business day.