AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TR10-K 1
TR10-K
On order
WIKA · Temperature measurement · Family TR10

Measuring insert

For resistance thermometer with flameproof enclosure (TR10-L)
Range
-196…600 °C
Output
4-20mA · HART
RoHSGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardATEXIECExEACEx UkraineINMETROCCCKCs-KOSHAPESOEMC directive EN 61326REACHCEEMC directiveII 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Gb0Ex ia IIC T6 ... T1 Ga XEx ia IIC T1 ...T6 GaEx ia IIC T3 ... T6 GaEx ia IIC T3 ... T6 GbEx ia IIC T1 ~ T6 GaEx e IIC T1 ~ T6 GbEx nA IIC T1 ~ T6 GcEx ia IIC T4…T6Ex ib IIC T4 ... T6Ex ia IIC T1…T6 GaEx ia IIC T1…T6 GbIECEx (in conjunction with ATEX)KCs - KOSHA PESOEAC (option)INMETRO (option)PESO (option)
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The measuring inserts for resistance thermometers described here are designed for installation in a thermometer model TR10-L. Operation without thermowell is appropriate only in special cases. The measuring insert is made of flexible, mineral-insulated sheathed cable. The sensor is located in the tip of the measuring insert. The measuring inserts are delivered with pressure springs to ensure that the measuring inserts are pressed down to the thermowell bottom.

The following versions are possible:

- ■ With mounted sleeve to suit inner diameter of the thermowell - ■ Without terminal block - ■ With transmitter

Type and number of sensors, accuracy and connection method can each be selected to suit the respective application.

for further approvals see page 2

Special features

  • Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
  • Made of mineral-insulated sheathed measuring cable
  • For all standard thermowell designs
  • Spring-loaded design
  • Explosion-protected versions are available for many approval types (see data sheet page 2)
Identification
ModelTR10-K
Product familyTR10
SubcategoryMeasuring insert
Measuring range
Temperature ranges−196…+600 °C · −100…+450 °C · −50…+250 °C · −50…+500 °C · −30…+300 °C · +0…+150 °C
Accuracy
Safety integrity level (SIL)SIL 2
Process conditions
Process temperature−196…+600 °C
Electrical characteristics
Output signal4-20mA · HART
Electrical connection2-wire, 3-wire, 4-wire
Materials
Probe materialstainless steel
Certifications and approvals
Certifications
RoHSGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardATEXIECExEACEx UkraineINMETROCCCKCs-KOSHAPESOEMC directive EN 61326REACHCEEMC directive
Explosion protection
II 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Gb0Ex ia IIC T6 ... T1 Ga XEx ia IIC T3 ... T6 GaEx ia IIC T3 ... T6 GbEx ia IIC T1 ~ T6 GaEx e IIC T1 ~ T6 GbEx nA IIC T1 ~ T6 GcEx ia IIC T4…T6Ex ib IIC T4 ... T6IECEx (in conjunction with ATEX)EAC Ex i Zone 0 gas 0Ex ia IIC T6...T1 Ga XEx Ukraine Ex i Zone 0 gas II 1G Ex ia IIC T1...T6 GaINMETRO Ex i Zone 0 gas Ex ia IIC T3...T6 GaCCC Hazardous areas Ex i Zone 0 gas Ex ia IIC T1~T6 GaKCs - KOSHA PESOGOST Zone 1 gas Ex ia IICT1…T6 GbKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEx i Zone 0 gas II 1G Ex ia IIC T1 ...T6 GaZone 1 gas II 2G Ex ia IIC T1 ...T6 Gb | European UnionIECEx (option)-in conjunction with ATEXEx i Zone 0 gas Ex ia IIC T1 ...T6 Ga | InternationalEAC (option)Ex i Zone 0 gas 0Ex ia IIC T6 ...T1 Ga X | Eurasian Economic CommunityEx i Zone 0 gas II 1G Ex ia IIC T1 ...T6 Ga | UkraineINMETRO (option)Ex i Zone 0 gas Ex ia IIC T3 ...T6 GaEx e Zone 1 Gas Ex e IIC T1 ~T6 GbEx n Zone 2 Gas Ex nA IIC T1 ~T6 Gc | ChinaEx i Zone 0 gas Ex ia IIC T4...T6Zone 1 gas Ex ib IIC T4...T6 | South KoreaPESO (option)Ex i Zone 0 gas Ex ia IIC T1...T6 GaZone 1 gas Ex ia IIC T1...T6 Gb | India
Additional details
Sensor typePt100
Sensor classA, B, AA
Probe length1100 mm
Probe diameter3 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application)European Union
International
IECEx (option) - in conjunction with ATEX
EAC (option) Hazardous areas - Ex i Zone 0 gas 0Ex ia IIC T6 ...T1 Ga XEurasian Economic Community
Ex Ukraine (option) Hazardous areas Ex i Zone 0 gas II 1G Ex ia IIC T1 ...T6 GaUkraine
INMETRO (option)
Hazardous areas - Ex i Zone 0 gas Ex ia IIC T3 ...T6 Ga Zone 1 gas Ex ia IIC T3 ...T6 Gb (option) 2)
CCC Hazardous areas -China
Ex i Zone 0 gas Ex ia IIC T1 ~ T6 GaSouth Korea
KCs - KOSHA (option) PESOIndia
-Hazardous areas
- Ex i Zone 0 gas Hazardous - Ex iZone 1 gas (option) areas Zone 0 gasEx ia IICT4…T6 Ex ib IIC T4 ...T6 Ex ia IICT1…T6 Ga
GOST (option)Russia
Zone 1 gas Ex ia IICT1…T6 Gb Metrology, measurement technology
KazInMetr (option)Kazakhstan
Metrology, measurement technology
LogoDescriptionCountry
-MTSCHS (option) Permission for commissioningKazakhstan
BelGIM (option) Metrology, measurement technologyBelarus
UkrSEPRO (option) Metrology, measurement technologyUkraine
Uzstandard (option) Metrology, measurement technologyUzbekistan
Connection method
Single elements1 x 2-wire 1 x 3-wire 1 x 4-wire
Dual elements2 x 2-wire 2 x 3-wire 2 x 4-wire 2)
Validity limits of class accuracy per EN 60751
ClassSensor construction
Wire-woundThin-film
Class B-196 ...+600 °C-50 ...+500 °C
Class A 3)-100 ...+450 °C-30 ...+300 °C
Class AA 3)-50 ...+250 °C0 ... 150 °C
View all (8)
Output signal 4 ... 20 mA, HART ® protocolModel T32Model T91.10
Data sheetTE 15.01TE 32.04TE 91.01
Output
4 ...20mAxxx
HART ® protocol-x-
Connection method
1 x 2-wire, 3-wire or 4-wirexxx
Measuring current< 0.2mA< 0.3mA0.8 ...1mA
Explosion protectionOptionalOptional-
Measuring insert length l 5 inmmTolerance inmm
75 ... 825+2 0
> 825+3 0
Measuring insert diameter Ø d inmmIndex per DIN 43735Tolerance inmm
3 1)Standard303 ±0.05
6Standard606 0 -0,1
8 (6 mmwith sleeve)Standard-8 0 -0,1
8Standard808 0 -0,1
1/8 in [3.17 mm] 1) 1/4 in [6.35 mm] 3/8 in [9.53 mm]On request--
Certification typeMeasurement accuracyMaterial certificate
2.2 test reportxx
3.1 inspection certificatexx
DKD/DAkkS calibration certificatex-