Bimetal thermometer with switch contacts
Description
Wherever the process temperature has to be indicated on-site and, at the same time, circuits need to be switched, the bimetal thermometer with switch contacts finds its use.
Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The switch contacts are adjustable over the full measuring range. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted via the window using a removable adjustment key (mounted on the cable socket).
for further approvals see page 8
Bimetal thermometer with switch contacts, model TGS55
Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond and below the desired set point.
As switch contacts, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts can be used.
Special features
- High reliability and long service life
- Universal application
- Case and stem from stainless steel
- Instruments with inductive contacts for use in hazardous areas
- Instruments with contacts for PLC applications
Build a TGS55 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- Nominal size100
- Connection locationback mount
- Connection designstandard, male thread
- switchinductive switch, version 831-N
- first switch operationmakes (1)
- second switch operationwithout
- Explosion protectionIECEx, ATEX type of protection ia with device category 2G and 2D
- Electrical connectionplug sidewise
- Unit°C
- Scale range-70 °C ... +30 °C
- 2nd Scalewithout
- Process connectionG 1/2 B
- Stem diameter6 mm
- Insertion length L1—
- Dampingwithout
- Special design featureswithout
- Certificateswithout
- Approvalswithout
- Additional ordering informationWithout
Finish your configuration
Select every option to submit the request.
| Model | TGS55 |
| Product family | TGS |
| Subcategory | With switch contacts |
| Temperature ranges | −70…+30 °C · −50…+50 °C · −30…+50 °C · −20…+140 °C · +0…+600 °C · −20…+60 °C · −20…+120 °C · +0…+60 °C · +0…+80 °C · +0…+100 °C · +0…+120 °C · +0…+160 °C · +0…+200 °C · +0…+250 °C · +0…+300 °C · +0…+400 °C · +0…+500 °C |
| Accuracy class | Class 1, Class 2 per DIN 16196 |
| Process connection | M20 x 1.5M24 x 1.5 femaleG ½ B½ NPTG ½ female½ NPT femalePlain, without thread |
| Process temperature | −60…+500 °C |
| Output signal | Inductive contact, model 831 · Electronic contact, model 830 E · Inductive contact · Electronic contact |
| Electrical connection | Cable socket, black Per VDE 0110 insulation group C/250 V Cable gland M20 x 1.5 |
| Probe material | Stainless steel 316SS |
| Ambient temperature | −50…+70 °C |
| IP rating | IP65 |
| Weight | 0.7 kg |
| Certifications | CERoHS |
| Explosion protection | EACEx ia Zone 1 gas II 2G Ex ia IIC T6/T5/T4 GbZone 21 dust II 2D Ex ia IIIB T85°C/T95°C/T100°C/T135°C DbIECEx Ex ia Zone 1 gas Ex ia IIC T6/T5/T4 GbATEX: Ex ia Zone 1 gas II 2G Ex ia IIC T6/T5/T4 Gb, Zone 21 dust II 2D Ex ia IIIB T85°C/T95°C/T100°C/T135°C DbIECEx: Ex ia IIC T6/T5/T4 Gb, Zone 21 dust Ex ia IIIB T85°C/T95°C/T100°C/T135°C Db |
| Sensor type | bimetal |
| Probe length | 63 mm |
| Probe diameter | 8 mm |
| Thermowell | No |
| Datasheet languages | EN |
| Basic information | |
|---|---|
| Standard | DIN 16196 |
| Nominal size in mm[in] | 100 [4"] |
| Window | ■ Instrument glass ■ Laminated safety glass ■ Clear non-splintering plastic |
| Connection location | ■ Back mount (axial) ■ Lower mount (radial) ■ Back mount, adjustable stem and dial |
| Connection design | → For drawings, see page 9 |
| S | Standard (threaded connection) 1) |
| 1 | Plain stem (without thread) |
| 2 | Male nut |
| 3 | Union nut |
| 4 | Compression fitting (sliding on stem) |
| 5 | Union nut and loose threaded connection |
| 'Adjustable stem and dial' case version | 90° swivelling and 360° rotatable |
| Dampening, case filling | ■ Without ■ With liquid dampening |
| Material (in contact with the environment) | |
| Case, bayonet ring | ■ Stainless steel 304SS ■ Stainless steel 316SS |
| Type of measuring element | Bimetal coil |
|---|---|
| Nominal effective range | |
| Continuous load (1 year) | Measuring range (DIN 16196) |
| Short time (max. 24 h) | Scale range (DIN 16196) |
| Accuracy per DIN 16196 1) | With single contact | With double contact |
|---|---|---|
| Stem diameter 6 mm[0.24 in] | Class 2 | Class 2 |
| Stem diameter 8 mm[0.31 in] | Class 1 | Class 2 |
| Stem diameter ≥ 10 mm[0.39 in] | Class 1 | Class 1 |
| Scale range in °C | Measuring range 1) in °C | Scale interval in °C | Error limit in °C | |
|---|---|---|---|---|
| Class 1 | Class 2 | |||
| -70 ... +30 | -60 ...+20 | 1 | 1.5 | 3.0 |
| -50 ... +50 | -40 ...+40 | 1 | 1.5 | 3.0 |
| -30 ... +50 | -20 ...+40 | 1 | 1.5 | 3.0 |
| -20 ... +60 | -10 ...+50 | 1 | 1.5 | 3.0 |
| -20 ... +120 | 0 ... 100 | 2 | 3.0 | 6.0 |
| -20 ... +140 | 0 ... 120 | 2 | 3.0 | 6.0 |
| 0 ... 60 | 10 ... 50 | 1 | 1.5 | 3.0 |
| 0 ... 80 | 10 ... 70 | 1 | 1.5 | 3.0 |
| 0 ... 100 | 10 ... 90 | 1 | 1.5 | 3.0 |
| 0 ... 120 | 10 ... 110 | 2 | 3.0 | 6.0 |
| 0 ... 160 | 20 ... 140 | 2 | 3.0 | 6.0 |
| 0 ... 200 | 20 ... 180 | 2 | 3.0 | 6.0 |
| 0 ... 250 | 30 ... 220 | 5 | 3.75 | 7.0 |
| 0 ... 300 | 30 ... 270 | 5 | 7.5 | 15.0 |
| 0 ... 400 | 50 ... 350 | 5 | 7.5 | 15.0 |
| 0 ... 500 | 50 ... 450 | 5 | 7.5 | 15.0 |
| 0 ... 600 | 100 ... 500 | 10 | 15.0 | 30.0 |
View all (20)
| Unit | ■ °C ■ °F ■ °C/°F (dual scale) | |
|---|---|---|
| Dial | ||
| Scale graduation | ■ Single scale ■ Dual scale | |
| Scale colour | Single scale | Black |
| Dual scale | Red | |
| Other colours on request | ||
| Material | Aluminium | |
| Pointer | ||
| Version | Adjustable pointer | |
| Pointer colour | Black | |
| Material | Aluminium |
| Thread size | ■ Plain, without thread ■ G½B ■ ½NPT ■ G½female ■ ½NPTfemale ■ M20 x 1.5 ■ M24 x 1.5 female |
|---|---|
| Material (in contact with the environment) | Stainless steel 316SS |
| Stem | |
| Diameter | ■ 6 mm[0.24 in] ■ 8 mm[0.31 in] ■ 10 mm[0.39 in] ■ 12 mm[0.47 in] |
| Material (wetted) | Stainless steel 316SS |
| Thermowell/protection tube | In principle, the operation of a mechanical thermometer is possible without a thermowell/protection tube with low process-side loading (low pressure, low viscosity and low flow velocities). However, in order to enable exchanging the thermometer during operation (e.g. instrument replacement or calibration) and to ensure a better protection of the measuring instrument and also the plant and the environment, it is advisable to use a thermowell/protection tube from the extensiveWIKA portfolio. →For further information on the wake frequency calculation, see Technical information |
| Output signal | |
|---|---|
| Type of contact | ■ Inductive contact, model 831 (→ see page 5) ■ Electronic contact, model 830 E (→ see page 6) |
| Switching technology | |
| Inductive contact, model 831 | ■ Suitable for use in hazardous areas with corresponding control unit (model 904.xx) ■ Long service life due to non-contact sensor ■ Low influence on the indication accuracy ■ Fail-safe switching at high switching frequency ■ Insensitive to corrosion ■ Also available in safety version |
| Electronic contact, model 830 E | ■ For direct triggering of a programmable logic controller (PLC) ■ Long service life due to non-contact sensor ■ Low influence on the indication accuracy ■ Fail-safe switching at high switching frequency ■ Insensitive to corrosion |
| Contact setting | ■ Contact adjustable, adjustment key mounted on the cable socket ■ Contacts fixed, without adjustment lock ■ Contact adjustment lock leaded (tamper-proof) ■ Contact adjustment key fixed |
| Connection method | Inductive contact |
|---|---|
| Number of switch contacts | Max. 2 switch contacts |
| Switching function | Contact versions: ■ 831-N ■ 831-SN, safety version 1) ■ 831-S1N, safety version 1) , inverted signal The switching function of each switch is indicated by index 1 or 2 |
| Model 831.1 | Normally open (clockwise pointer motion) |
| Model 831.2 | Normally closed (clockwise pointer motion) |
| Switch point setting | Set pointers of the contact pressure gauges are freely adjustable over the full scale range |
| Setting range (recommended) | 10 ... 90 %of the scale range (0 ... 100 %onrequest) |
| Distance between switch points | Up to 2 contacts can be set to an identical set point. For a version with 3 contacts this is not possible.The left (no. 1) or right (no. 3) contact may not be set to the same set point as the other 2 contacts.The required displacement is approx. 30°, optionally to the right or to the left. |
| Switching current | Depending on the isolating amplifier/control unit used (→ see data sheet AC 08.01) |
| Switching voltage | Depending on the isolating amplifier/control unit used (→ see data sheet AC 08.01) |
| Switching power | Depending on the isolating amplifier/control unit used (→ see data sheet AC 08.01) |
| Permissible temperature ranges in hazardous areas | |
| T6 | -20 ...+60 °C [-4 ...+140 °F] |
| T5 ...T1 | -20 ...+70 °C [-4 ...+158 °F] |
| T135°C | -20 ...+70 °C [-4 ...+158 °F] |
| Model | Version | Ex version |
|---|---|---|
| 904.28 KFU8 - SR2 - Ex1.W | 1 contact | Yes |
| 904.29 KFU8 - SR2 - Ex2.W | 2 contacts | Yes |
| 904.30 KHA6 - SH - Ex1 | 1 contact | Yes - Safety version |
| 904.33 KFD2 - SH - Ex1 | 1 contact | Yes - Safety version |
| 904.25 MSR 010-I | 1 contact | No |
| 904.26 MSR 020-I | 2 contacts | No |
| 904.27 MSR 011-I | Two-point control | No |
| Connection method | Electronic contact (PNP transistor) |
|---|---|
| Number of switch contacts | Max. 2 switch contacts |
| Switching function | Contact versions: ■ 2-wire system ■ 3-wire system The switching function of each switch is indicated by index 1 or 2 |
| Model 830 E.1 | Normally open (clockwise pointer motion) |
| Model 830 E.2 | Normally closed (clockwise pointer motion) |
| Setting range (recommended) | 10 ... 90 %of the scale range (0 ... 100 %onrequest) |
| Distance between switch points | Up to 2 contacts can be set to an identical set point. For a version with 3 contacts this is not possible.The left (no. 1) or right (no. 3) contact may not be set to the same set point as the other 2 contacts.The required displacement is approx. 30°, optionally to the right or to the left. |
| Switching current | ≤ 100mA |
| Switching voltage | DC 10 ...30V |
| Type of output | PNP transistor |
| Residual ripple | Max.10% |
| No-load current | ≤ 10mA |
| Residual current | ≤ 100 µA |
| Voltage drop (with I max. ) | ≤ 0.7V |
| Reverse polarity protection | Conditional U B (the switched output 3 or 4 must never be set directly to minus) |
| Anti-inductive protection | 1 kV, 0.1 ms, 1 kΩ |
| Oscillator frequency | Approx. 1,000 kHz |
| EMC | Per EN 60947-5-2 |
| Connection type | ■ Cable socket, black PerVDE 0110 insulation group C/250V Cable gland M20 x 1.5 ■ Connector ■ Rear cable outlet |
|---|---|
| Wire cross-section | 6 screw terminals + PE for conductor cross-section 2.5 mm² |
| Cable diameter | → See dimensions from page 10 |
| Pin assignment | Connection details are given on the product label of the instrument. Connection terminals and ground terminals are appropriately marked. |
| Material | PA 6 (polyamide) |
| Ambient temperature range (at the case) 1) | -20 ...+60 °C [-4 ...+140 °F] |
|---|---|
| Storage temperature range 1) | |
| Without liquid dampening | -50 ...+70 °C [-58 ...+158 °F] |
| With liquid dampening | -40 ...+70 °C [-40 ...+158 °F] |
| Max. operating pressure at stem | Max. 25 bar [362.59 psi], static |
| Ingress protection (IP code) per IEC/EN 60529 | ■ IP65 ■ IP66 |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective | ||
| Low voltage directive | ||
| RoHS directive |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| IECEx 1) Hazardous areas - Ex ia Zone 1 gas Ex ia IIC T6/T5/T4 Gb Zone 21 dust Ex ia IIIB T85°C/T95°C/T100°C/T135°C Db | International | |
| EAC EMCdirective Hazardous areas 1) | Eurasian Economic Community | |
| KazInMetr Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS Permission for commissioning | Kazakhstan |
| UkrSEPRO Metrology, measurement technology | Ukraine | |
| Ex Ukraine Hazardous areas | Ukraine | |
| Uzstandard Metrology, measurement technology | Uzbekistan | |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) | Canada |
| Certificates | ■ 2.2 test report ■ 3.1 inspection certificate with 3 test points (optionally with 5 test points) |
|---|---|
| Calibration | DAkkS calibration certificate |
| Nominal size | i i l 2 l SW 1 Dimensions inmm l 1 | |||
|---|---|---|---|---|
| NS | d 1 | Ød d 1 | 1 a for axial | i 2 l a for adjustable stem and dial Ø d |
| Bauform 100 | SW 5 18 | 8 | l 2 15 | 25 |
| Nominal size | ca.40 l l 2 1 Process connection | Dimensions inmm 3073050.06 | ||
|---|---|---|---|---|
| NS | G | i | SW | Ø d |
| 100 | G½B | 8.5 L | 27 | 8 |
| G¾B | 10.5 | 32 | 8 | |
| M24 x 1.5 | 13.5 | 32 | 8 |
| Nominal size | l a l 2 G SW Process connection | Dimensions inmm | |||
|---|---|---|---|---|---|
| SW NS | G | 1 i | SW | d 4 | 3073050.06 Ø d Bauform |
| 100 | G½B | 14 | d d 27 | 26 | 8 Design 1 |
| G¾B | 16 | Ø 32 | 32 | Bauform 3 8 | |
| ½NPT | 19 | 22 | - | 3073050.06 Design 3 8 | |
| ¾NPT | 20 | 30 | - | 8 |
| Nominal size | i i Process connection | Dimensions inmm Bauform Design | ||
|---|---|---|---|---|
| 25 NS | SW G | i | SW | Ø d |
| Ø22 100 | G½B | 20 | G 27 | 8 |
| l Nominal size | Process connection | Dimensions inmm | |||
|---|---|---|---|---|---|
| l 1 NS | G | i | SW | d 4 | Ø d |
| 100 | G½B | 14 | 27 | 26 | 8 |
| G | ca.40 Ø d d G¾B | 16 | 32 | 32 | 8 |
| M18 x 1.5 | L 12 | 24 | 23 | 8 | |
| ½NPT | 19 | 22 | - | 8 | |
| l 2 | ¾NPT | 20 | 30 | - | 8 |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →17 standard articles of family TGS
If you know the code — pick directly. If not — use the configurator in mode “01”.