AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
990.45 1
990.45
On order
WIKA · Pressure measurement · Family 990

Diaphragm seal with flange connection

High-temperature version to 450 °C [842 °F], with internal diaphragm
EN 10204 2.2EN 10204 3.1
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Diaphragm seals are used for the protection of pressure measuring instruments in applications with difficult media. In diaphragm seal systems, the diaphragm of the diaphragm seal effects the separation of the instrument and the medium. The pressure is transmitted to the measuring instrument via the system fill fluid which is inside the diaphragm seal system.

For the implementation of demanding customer applications, there is a wide variety of designs, materials and system fill fluids available.

For further technical information on diaphragm seals and diaphragm seal systems, see IN 00.06 'Application, operating principle, designs'.

High-temperature version, model 990.45

Model 990.45 is a high-temperature version consisting of the upper and lower body of a diaphragm seal. The lower body of the diaphragm seal can optionally be designed with flushing connections.

These components have been developed explicitly for applications with very hot media. The process connection is available in the established dimensions in line with the usual standards for this market.

Mounting of the diaphragm seal to a measuring instrument is usually made via a flexible capillary.

Diaphragm seal systems with model 990.45

Special features

  • Common standards and nominal widths available
  • When special materials are selected, all wetted parts are made of the selected material
  • Version with integrated flushing connections available
Identification
Model990.45
Product family990
SubcategoryDiaphragm seal with flange connection
Process conditions
Process connection
DN 25DN 50DN 801"2"3"1 ½"
Process temperature−20…+450 °C
Materials
Case materialStainless steel 1.4404 (316L)
Wetted parts materialStainless steel 1.4878 (321H), Stainless steel 1.4435 (316L), Stainless steel 1.4435 (316L) with gold plating
Operating environment
Ambient temperature−20…+60 °C
Certifications and approvals
Certifications
EN 10204 2.2EN 10204 3.1
Additional details
Datasheet languagesEN
Tables from datasheet
Operating conditions
Medium temperature range 1) 2)-20 ...+450 °C [-4 ...+842 °F]
Ambient temperature range-20 ...+60 °C [-4 ...+140 °F]
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy for diaphragm seal systems) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy for diaphragm seal systems)
DNPNDimensions in mm[in]
D 1D 2kHd 1d 2d 3d 4b 1b 2f
2540115 [4.528]200 [7.874]85 [3.346]180 [7.087]43 [1.693]4 x 14 [4 x 0.551]34.5 [1.358]68 [2.677]18 [0.709]34 [1.339]2 [0.079]
5040165 [6.496]200 [7.874]125 [4.921]182 [7.165]78 [3.071]4 x 18 [4 x 0.709]62 [2.441]102 [4.016]20 [0.787]34 [1.339]2 [0.079]
8040200 [7.874]200 [7.874]160 [6.299]186 [7.323]112 [4.409]8 x 18 [8 x 0.709]95 [3.74]138 [5.433]24 [0.945]34 [1.339]2 [0.079]
DNClassDimensions in mm[in]
D 1D 2kHd 1d 2d 3d 4b 1b 2f
1"400 / 600125 [4.921]210 [8.268]88.9 [3.50]209 [8.228]48 [1.890]4 x 19 [4 x 0.748]26.5 [1.043]70 [2.756]23.9 [0.941]40 [1.575]]6.4 [0.252]
1 ½"400 / 600155 [6.102]210 [8.268]114.3 [4.500]214 8.425]64 [2.520]4 x 22 [4 x 0.866]40.9 [1.61]90.5 [3.563]28.7 [1.130]40 [1.575]]6.4 [0.252]
2"400 / 600165 [6.496]210 [8.268]127 [5.000]218 [8.583]78 [3.071]8 x 19 [8 x 0.748]52.5 [2.067]108 [4.252]33.4 [1.315]40 [1.575]]8 [0.315]
3"400 / 600210 [8.268]210 [8.268]168.3 [6.626]225 [8.74]101 [3.976]8 x 22 [8 x 0.866]78 [3.071]146 [5.748]39.8 [1.567]40 [1.575]]8 [0.315]
View all (8)
ModelDescriptionOrder number
910.27Flushing ring for flange-connection diaphragm seals →See data sheet AC 09.05On request
IVMMonoflange, process and instrument version →See data sheet AC 09.17On request
IBF2, IBF3Monoblock with flange connection →See data sheet AC 09.25On request
910.16Instrument mounting bracket form H per DIN 16281, 100 mm, aluminium, black9091858
Instrument mounting bracket form H per DIN 16281, 100 mm, stainless steel9091882
→See data sheet AC 09.05On request
MaterialUnified numbering system (UNS)
Stainless steel 316L (1.4404 or 1.4435)S31603
Stainless steel 904L (1.4539)N08904
Stainless steel 321 (1.4541)S32100
Stainless steel 316Ti (1.4571)S31635
Stainless steel 1.4466 (urea grade)S31050
Duplex 2205 (1.4462)S31803
Superduplex 1.4410S32750
Tantalum (also lining)R05200
Hastelloy C276 (2.4819)N01276
Hastelloy C22 (2.4602)N06022
Inconel 600 (2.4816)N06600
Incoloy 825 (2.4858)N08825
Inconel 625 (2.485)N06625
Monel 400 (2.4360)N04400
Nickel 200 (2.4066)N02200
Nickel 201 (2.4068)N02201
Titanium 3.7035 (class 2)R50400
Titanium 3.7235 (class 7)R52400
Zirconium GR702R60702
DesignationIdenti- fication numberSolidi- fication pointBoiling/ degradation pointDensity at 25 °CKin.Viscosity at 25 °CRemark
KN°C°Cg/cm³cSt
Silicone oil2-45+3000.9654.5Universal application
Glycerine7-35+2401.26759.6FDA 21 CFR 182.1320
Silicone oil17-90+2000.924.4Low temperatures
Halocarbon21-60+1751.8910.6Oxygen 1) and chlorine
Methylcyclopentane30-130+600.740.7For very low temperatures
High-temperature silicone oil32-25+4001.0647.1For high temperatures
Neobee® M-2059-35+2600.9210.0FDA 21 CFR 172.856, 21 CFR 174.5
DI water64+4+851.000.9For ultrapure media
Silicone oil68-75+2500.9310.3
DI water/propanol mixture75-30+600.923.6For ultrapure media
Medicinal white mineral oil92-15+2600.8545.3FDA 21 CFR 172.878, 21 CFR 178.3620(a); USP, EP, SP
Maximum temperatureMaximum oxygen pressure
to 60 °C50 bar
> 60 °C to 100 °C30 bar
> 100 °C to 175 °C25 bar