Fault · SINAMICS G120C, G130, G150, S120, S150

F08510PN/COMM BOARD: Send configuration data invalid

What it means

The drive raises F08510 when the COMM BOARD does not accept the send configuration data. The message value carries the return value of the send-configuration data check; it is read in r0949 and interpreted as a decimal number. Depending on how the drive is configured, the same condition can also be signalled as an alarm (A) instead of a fault; as an alarm it triggers no automatic reaction and requires no acknowledgement.

Why it appears

  • The COMM BOARD did not accept the send configuration data.

What to check

  1. Check the send configuration data.

Reading the message value

  • The drive stores the return value of the send-configuration data check as the fault value; read it in r0949 and interpret it as a decimal number.

Parameters the manual names

  • r0949 — read here the fault value of F08510: the return value of the send-configuration data check, to be interpreted decimal.

Acknowledging and restarting

Acknowledge the fault immediately. The remedy the manuals give is to check the send configuration data. If the condition is signalled only as an alarm (A), no acknowledgement is required.

What differs between the drive families

Straight from the manuals' own fields — F08510 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150Infeed: OFF1 (OFF2) Servo: OFF1 (OFF2, OFF3) Vector: OFF1 (OFF2, OFF3) Hla: OFF1 (OFF2, OFF3)IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2919
G130, G150Vector: OFF1 (OFF2, OFF3) Infeed: OFF1 (OFF2)IMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1634
G120CSINAMICS G120C Converters · p. 386

The drives this code lives on

F08510 is described for G120C, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F08510 mean on a SINAMICS drive?

The COMM BOARD did not accept the send configuration data. The fault value in r0949 is the return value of the send-configuration data check, to be interpreted as a decimal number.

How do I fix fault F08510?

Check the send configuration data — this is the remedy the manuals give — and then acknowledge the fault immediately.

Can F08510 also appear as an alarm?

Yes. Depending on the drive configuration, the same condition can be signalled as an alarm (A); as an alarm it causes no reaction and requires no acknowledgement.

Which SINAMICS converters describe fault F08510?

The manuals describe the message for SINAMICS G120C, G130, G150, S120 and S150.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.