What it means
The drive raises F08510 when the COMM BOARD does not accept the send configuration data. The message value carries the return value of the send-configuration data check; it is read in r0949 and interpreted as a decimal number. Depending on how the drive is configured, the same condition can also be signalled as an alarm (A) instead of a fault; as an alarm it triggers no automatic reaction and requires no acknowledgement.
Why it appears
- The COMM BOARD did not accept the send configuration data.
What to check
- Check the send configuration data.
Reading the message value
- The drive stores the return value of the send-configuration data check as the fault value; read it in r0949 and interpret it as a decimal number.
Parameters the manual names
- r0949 — read here the fault value of F08510: the return value of the send-configuration data check, to be interpreted decimal.
Acknowledging and restarting
Acknowledge the fault immediately. The remedy the manuals give is to check the send configuration data. If the condition is signalled only as an alarm (A), no acknowledgement is required.
What differs between the drive families
Straight from the manuals' own fields — F08510 is not described identically everywhere.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| S120, S150 | Infeed: OFF1 (OFF2) Servo: OFF1 (OFF2, OFF3) Vector: OFF1 (OFF2, OFF3) Hla: OFF1 (OFF2, OFF3) | IMMEDIATELY | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS S120, S150 List Manual · p. 2919 |
| G130, G150 | Vector: OFF1 (OFF2, OFF3) Infeed: OFF1 (OFF2) | IMMEDIATELY | Error in the parameterization / configuration / commissioning procedure (18) | None | SINAMICS G130, G150 List Manual · p. 1634 |
| G120C | — | — | — | — | SINAMICS G120C Converters · p. 386 |
The drives this code lives on
F08510 is described for G120C, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does fault F08510 mean on a SINAMICS drive?
The COMM BOARD did not accept the send configuration data. The fault value in r0949 is the return value of the send-configuration data check, to be interpreted as a decimal number.
How do I fix fault F08510?
Check the send configuration data — this is the remedy the manuals give — and then acknowledge the fault immediately.
Can F08510 also appear as an alarm?
Yes. Depending on the drive configuration, the same condition can be signalled as an alarm (A); as an alarm it causes no reaction and requires no acknowledgement.
Which SINAMICS converters describe fault F08510?
The manuals describe the message for SINAMICS G120C, G130, G150, S120 and S150.