SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Fault · SINAMICS G130, G150, S120, S150

F06907Braking Module internal overtemperature

What it means

F06907 is raised when the temperature sensor connected to the braking resistor signals an overtemperature. The Braking Module is still active at this point. This is the early stage of the condition: if the overtemperature persists for more than 60 s, the drive outputs F06908 and switches the Braking Module off. The manual cross-references r3687, the digital Braking Module pre-alarm overtemperature signal, for this fault.

Why it appears

  • The temperature sensor wired to the braking resistor reports an overtemperature.

What to check

  1. Reduce the temperature at the sensor while the Braking Module is still active — if the overtemperature persists for more than 60 s, the drive outputs F06908 and switches the Braking Module off.
  2. Check the temperature sensor connection.

Parameters the manual names

  • r3687 — binector output (BO) "Digital Braking Module pre-alarm overtemperature": the overtemperature pre-alarm signal of the digital Braking Module, which the manual cross-references for this fault.

Acknowledging and restarting

Reduce the temperature at the sensor and check the temperature sensor connection, then acknowledge the fault; the drive can then be restarted. If the overtemperature has not actually been cleared, the drive outputs F06908 after 60 s and switches the Braking Module off, so the temperature and the sensor connection must genuinely be put right before the restart.

The same on every family

Every manual that describes F06907 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150OFF2 (NONE, OFF1)IMMEDIATELYBraking Module faulted (14)NoneSINAMICS G130, G150 List Manual · p. 1532
S120, S150OFF2 (NONE, OFF1)IMMEDIATELYBraking Module faulted (14)NoneSINAMICS S120, S150 List Manual · p. 2775

The drives this code lives on

F06907 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F06907 mean on a SINAMICS drive?

The temperature sensor connected to the braking resistor has signalled an overtemperature. The Braking Module is still active when this fault appears.

What happens if F06907 persists?

If the overtemperature persists for more than 60 s, the drive outputs F06908 and switches the Braking Module off.

How do I clear fault F06907?

Reduce the temperature at the sensor and check the temperature sensor connection, then acknowledge the fault and restart the drive.

Which parameter is linked to F06907?

r3687 — the digital Braking Module pre-alarm overtemperature binector output — is the signal the manual cross-references for this fault.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F06xxx group · SINAMICS manuals · Siemens manuals