What it means
F06906 is issued when the internal Braking Module reports a fault and is therefore inhibited. The underlying condition is one of two: an overcurrent or an excessively high I2t value in the Braking Module. The manuals describe the message identically for the G130, G150, S120 and S150, and the same condition can also be signalled as an alarm (A), depending on the drive's configuration. The message is additionally displayed via the BO p3686, and the associated Digital Braking Module fault signal can be read at r3686.
Why it appears
- The internal Braking Module has detected an overcurrent or an excessively high I2t value; it reports a fault and is inhibited as a result.
What to check
- Read the fault value in r0949 bitwise binary: bit 0 set means the I2t value was exceeded, bit 1 set means overcurrent.
- Reduce the number of braking operations — this is the remedy the manuals give.
- Use r3686 (BO: Digital Braking Module fault) to view the Braking Module fault signal belonging to this message.
Reading the message value
- The drive stores the fault value in r0949; the manual specifies that it is to be interpreted bitwise binary.
- Bit 0 = 1: I2t exceeded.
- Bit 1 = 1: overcurrent.
Parameters the manual names
- r0949 — fault value: read it bitwise binary to see which condition inhibited the Braking Module (bit 0 = I2t exceeded, bit 1 = overcurrent).
- r3686 — BO: Digital Braking Module fault: shows the Braking Module fault signal associated with this message.
Acknowledging and restarting
Acknowledge the fault immediately. Beyond that, the manuals name no further restart procedure: the remedy is to reduce the number of braking operations. When the same condition is present as an alarm (A) rather than a fault, the manual specifies no acknowledgement for it.
The same on every family
Every manual that describes F06906 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| G130, G150 | NONE | IMMEDIATELY | Braking Module faulted (14) | None | SINAMICS G130, G150 List Manual · p. 1532 |
| S120, S150 | NONE | IMMEDIATELY | Braking Module faulted (14) | None | SINAMICS S120, S150 List Manual · p. 2774 |
The drives this code lives on
F06906 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does SINAMICS fault F06906 mean?
The internal Braking Module reports a fault because of an overcurrent or an excessively high I2t value and is inhibited as a result.
How do I clear fault F06906?
Reduce the number of braking operations, then acknowledge the fault immediately. The fault value in r0949 shows whether bit 0 (I2t exceeded) or bit 1 (overcurrent) is set.
Where can I read the fault value of F06906?
In r0949, interpreted bitwise binary: bit 0 = 1 means the I2t value was exceeded, bit 1 = 1 means overcurrent. The message is also displayed via the BO p3686.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.
All SINAMICS codes: fault and alarm codes · the F06xxx group · SINAMICS manuals · Siemens manuals