SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Fault · SINAMICS G120, G130, G150, S120, S150

F02080Trace: Parameterization deleted due to unit changeover

What it means

F02080 reports that the trace configuration saved in the drive unit is gone. The drive removes the saved trace configuration when a unit changeover takes place, and it does the same when the reference parameters are altered. The fault therefore means that the trace has to be started again before a trace configuration exists in the drive unit.

Why it appears

  • A unit changeover took place, and the trace configuration saved in the drive unit was removed with it.
  • The reference parameters were altered; this deletes the saved trace configuration as well.

What to check

  1. Restart the trace so that a valid trace configuration is present in the drive unit again.
  2. Should the fault reappear, check which of the two documented triggers occurred — a unit changeover or altered reference parameters.

Acknowledging and restarting

The fault is cleared with a normal acknowledgement; it can be acknowledged straight away, without switching the drive off and on first. Acknowledging alone restores nothing — the trace must be restarted so that a configuration exists in the drive unit again.

What differs between the drive families

Straight from the manuals' own fields — F02080 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1507
S120, S150NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2733
G120NONEIMMEDIATELYError in the parameterization / configuration / commissioning procedure (18)SINAMICS G120 · p. 864

The drives this code lives on

F02080 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F02080 mean on a SINAMICS drive?

It reports that the trace configuration saved in the drive unit has been deleted, either by a unit changeover or by altered reference parameters.

How do I clear F02080?

Restart the trace so that a configuration exists in the drive unit again, then acknowledge the fault. The acknowledgement is possible straight away, without a power-down.

Why did my trace configuration disappear?

The manual gives two triggers for the deletion: a unit changeover, or a change to the reference parameters. Either one removes the saved trace configuration from the drive unit.

Which SINAMICS drives report F02080?

The manuals for G120, G130, G150, S120 and S150 describe the code with the same cause and the same remedy: restart the trace.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the F02xxx group · SINAMICS manuals · Siemens manuals