Alarm · SINAMICS G130, G150, S120, S150

A02008Function generator: Drive specified a multiple number of times

What it means

The function generator reports that the drive object specified for its connection is already specified — in other words, the same drive object has been specified a multiple number of times. The alarm value identifies which drive object is affected.

Why it appears

  • The drive object chosen for the connection is already specified: this drive object has been specified a multiple number of times.

What to check

  1. Read the alarm value in r2124 as a decimal number — it contains the drive object number of the drive object that has been specified a multiple number of times.
  2. Specify a different drive object for the connection.

Reading the message value

  • The alarm value is stored in r2124 and must be interpreted as a decimal number.
  • Read as a decimal, it is the drive object number of the drive object that is specified a multiple number of times.

Parameters the manual names

  • r2124 (alarm value) — holds the alarm value for this alarm; interpreted as a decimal number it names the drive object number that has been specified more than once.

Acknowledging and restarting

As the manual puts it: The alarm is reset as follows: remove the cause of this alarm, restart the function generator. So first remove the cause — by specifying a different drive object — and then restart the function generator.

The same on every family

Every manual that describes A02008 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS S120, S150 List Manual · p. 2725
G130, G150NONENONEError in the parameterization / configuration / commissioning procedure (18)NoneSINAMICS G130, G150 List Manual · p. 1500

The drives this code lives on

A02008 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A02008 mean on a SINAMICS drive?

It comes from the function generator: the drive object that was specified for the connection is already specified, i.e. the same drive object has been specified a multiple number of times.

How do I fix A02008?

Specify a different drive object for the connection, then restart the function generator — the alarm is reset once its cause has been removed.

Which drive object is meant when A02008 appears?

The alarm value in r2124, interpreted as a decimal number, contains the drive object number of the drive object that has been specified a multiple number of times.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A02xxx group · SINAMICS manuals · Siemens manuals